Skip to main content
QUICK REVIEW

[Paper Review] Development and testing of cost-effective, 6 cm x 6 cm MCP-based photodetectors for fast timing applications

Jingbo Wang, K. Byrum|arXiv (Cornell University)|Apr 26, 2016
Advanced Optical Sensing TechnologiesPhysics and Astronomy17 references5 citations
TL;DR

This paper presents the development and testing of low-cost, 6 cm × 6 cm microchannel plate (MCP)-based photodetectors using atomic layer deposition (ALD)-functionalized MCPs for fast timing applications. The prototypes achieved sub-60 ps time resolution in single photoelectron mode and sub-0.8 mm position resolution, demonstrating high performance at reduced cost and scalable manufacturing via a small single tube processing system (SmSTPS).

ABSTRACT

Micro-channel plate (MCP)-based photodetectors are capable of picosecond level time resolution and sub-mm level position resolution, which makes them a perfect candidate for the next generation large area photodetectors. The large-area picosecond photodetector (LAPPD) collaboration is developing new techniques for making large-area photodetectors based on new MCP fabrication and functionalization methods. A small single tube processing system (SmSTPS) was constructed at Argonne National Laboratory (ANL) for developing scalable, cost-effective, glass-body, 6 cm x 6 cm, picosecond photodetectors based on MCPs functionalized by Atomic Layer Deposition (ALD). Recently, a number of fully processed and hermitically sealed prototypes made of MCPs with 20 micron pores have been fabricated. This is a significant milestone for the LAPPD project. These prototypes were characterized with a pulsed laser test facility. Without optimization, the prototypes have shown excellent results: The time resolution is ~57 ps for single photoelectron mode and ~15 ps for multi-photoelectron mode; the best position resolution is < 0.8 mm for large pulses. In this paper, the tube processing system, the detector assembly, experimental setup, data analysis and the key performance will be presented.

Motivation & Objective

  • To develop a scalable, cost-effective fabrication process for large-area MCP-based photodetectors.
  • To enable picosecond-level time resolution and sub-millimeter position resolution in 6 cm × 6 cm detectors.
  • To demonstrate the feasibility of using ALD for functionalizing MCPs in a scalable tube processing system.
  • To validate detector performance using a pulsed laser test facility with minimal optimization.
  • To advance the Large-Area Picosecond Photodetector (LAPPD) project with a manufacturable, hermetically sealed prototype.

Proposed method

  • Design and construction of a small single tube processing system (SmSTPS) at Argonne National Laboratory for scalable MCP fabrication.
  • Application of atomic layer deposition (ALD) to functionalize 20 µm pore MCPs for enhanced electron multiplication and timing performance.
  • Assembly of hermetically sealed 6 cm × 6 cm photodetector tubes using glass bodies and ALD-coated MCPs.
  • Use of a pulsed laser test facility to characterize time and position resolution across single and multi-photoelectron modes.
  • Implementation of data analysis techniques to extract time resolution and position resolution from detector signals.
  • Employment of a modular, low-cost processing system to enable future scaling to larger detector arrays.

Experimental results

Research questions

  • RQ1Can a cost-effective, scalable processing system produce high-performance MCP-based photodetectors with picosecond timing resolution?
  • RQ2What is the achievable time resolution in single and multi-photoelectron modes using ALD-functionalized 20 µm MCPs?
  • RQ3What level of position resolution can be achieved with the fabricated 6 cm × 6 cm MCP detectors?
  • RQ4How does the performance of the prototype compare to optimized commercial systems without further tuning?
  • RQ5Can hermetic sealing and glass-body construction be successfully integrated into a scalable manufacturing process?

Key findings

  • The fabricated 6 cm × 6 cm MCP-based photodetectors achieved a time resolution of ~57 ps in single photoelectron mode without optimization.
  • In multi-photoelectron mode, the time resolution improved to ~15 ps, indicating excellent signal-to-noise performance.
  • The best position resolution achieved was < 0.8 mm for large pulses, demonstrating sub-millimeter spatial resolution.
  • The use of ALD-functionalized 20 µm pore MCPs enabled high electron gain and fast timing response.
  • The prototypes were hermetically sealed and fully processed, representing a significant milestone for the LAPPD project.
  • The results validate the scalability and cost-effectiveness of the SmSTPS approach for large-area photodetector production.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.