Skip to main content
QUICK REVIEW

[Paper Review] Differential atom interferometry with $^{87}$Rb and $^{85}$Rb for testing the UFF in STE-QUEST

Christian Schubert, Jonas T. Hartwig|arXiv (Cornell University)|Dec 20, 2013
Cold Atom Physics and Bose-Einstein CondensatesPhysics and Astronomy3 references17 citations
TL;DR

This paper presents a dual-species 87Rb/85Rb atom interferometer scheme for the STE-QUEST space mission to test the universality of free fall (UFF) with a target sensitivity of 2 parts in 10^15. By using symmetric Raman beam splitters in microgravity, the method suppresses environmental noise through common-mode rejection and achieves a 2.5×10^−9 suppression ratio for linear accelerations and vibrations, enabling high-precision differential acceleration measurements over 5-second free evolution times.

ABSTRACT

In this paper we discuss in detail an experimental scheme to test the universality of free fall (UFF) with a differential $^{87}$Rb / $^{85}$Rb atom interferometer applicable for extended free fall of several seconds in the frame of the STE-QUEST mission. This analysis focuses on suppression of noise and error sources which would limit the accuracy of a violation measurement. We show that the choice of atomic species and the correctly matched parameters of the interferometer sequence are of utmost importance to suppress leading order phase shifts. In conclusion we will show the expected performance of $2$ parts in $10^{15}$ of such an interferometer for a test of the UFF.

Motivation & Objective

  • To develop a high-precision differential atom interferometer using 87Rb and 85Rb isotopes for testing the universality of free fall (UFF) in space.
  • To suppress environmental noise sources—especially vibrations and accelerations—through common-mode rejection using two closely matched atomic species.
  • To achieve a target sensitivity of 2 parts in 10^15 for the Eötvös ratio, surpassing current ground-based limits.
  • To evaluate and mitigate leading-order phase errors from magnetic field gradients, wavefront curvature, and spurious accelerations in a space-borne microgravity environment.
  • To establish a robust error budget and performance model for the STE-QUEST mission’s atom interferometer payload.

Proposed method

  • The experiment employs a Mach-Zehnder geometry with symmetric Raman beam splitters to coherently split and recombine matter waves of 87Rb and 85Rb simultaneously.
  • A 5-second free evolution time is enabled by microgravity conditions in the STE-QUEST orbit, maximizing phase accumulation for UFF sensitivity.
  • The expansion rate of 82 µm/s is carefully matched between the two species to minimize wavefront curvature-induced phase biases.
  • Common-mode rejection is leveraged by sharing the same retroreflected beam-splitting light field, suppressing vibrations and linear accelerations with a suppression ratio of 2.5×10^−9.
  • A reversal of the internal state preparation is used to cancel residual magnetic field gradient effects.
  • Systematic errors such as spurious accelerations, gravity gradients, and beam splitter inaccuracies are evaluated and shown to be compatible with the target sensitivity.

Experimental results

Research questions

  • RQ1How can differential atom interferometry with 87Rb and 85Rb suppress environmental noise to enable sub-10^−15 level UFF tests in space?
  • RQ2What are the dominant systematic phase shifts in a dual-species interferometer, and how can they be mitigated in microgravity?
  • RQ3To what extent can common-mode rejection of vibrations and accelerations be achieved with two isotopes of the same element?
  • RQ4How do wavefront curvature, magnetic field gradients, and beam splitter imperfections affect the differential phase, and what corrections are needed?
  • RQ5What is the achievable sensitivity of the STE-QUEST atom interferometer to the Eötvös ratio, given the mission’s orbit and payload constraints?

Key findings

  • The dual-species 87Rb/85Rb interferometer achieves a suppression ratio of 2.5×10^−9 for linear accelerations and vibrations due to common-mode rejection.
  • The interferometer design enables a 5-second free evolution time in microgravity, maximizing phase sensitivity for UFF testing.
  • The expansion rates of both species are matched to 82 µm/s to cancel wavefront curvature-induced phase biases.
  • The estimated sensitivity to the Eötvös ratio is better than 5.3×10^−14 per revolution, leading to an integrated sensitivity of better than 2×10^−15 after 1.5 years of operation.
  • Systematic errors, including spurious accelerations, magnetic field gradients, and beam splitter inaccuracies, are estimated to be compatible with the target inaccuracy of 2×10^−15.
  • The error budget shows that all major noise sources are within acceptable limits, and the system is designed to be shot-noise-limited with a differential acceleration sensitivity of 3×10^−12 m/s² per 20-second cycle.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.