[Paper Review] Direct data-driven control of constrained linear parameter-varying systems: A hierarchical approach
This paper proposes a hierarchical, direct data-driven control method for constrained linear parameter-varying (LPV) systems, bypassing system identification by designing an inner LPV controller to match a simple reference model and an outer model predictive controller (MPC) to enforce input/output constraints and improve performance. The approach enables constraint handling and reduces reliance on accurate reference model selection, outperforming prior direct data-driven methods in simulation and experimental validation on an RC circuit with switching load.
In many nonlinear control problems, the plant can be accurately described by a linear model whose operating point depends on some measurable variables, called scheduling signals. When such a linear parameter-varying (LPV) model of the open-loop plant needs to be derived from a set of data, several issues arise in terms of parameterization, estimation, and validation of the model before designing the controller. Moreover, the way modeling errors affect the closed-loop performance is still largely unknown in the LPV context. In this paper, a direct data-driven control method is proposed to design LPV controllers directly from data without deriving a model of the plant. The main idea of the approach is to use a hierarchical control architecture, where the inner controller is designed to match a simple and a-priori specified closed-loop behavior. Then, an outer model predictive controller is synthesized to handle input/output constraints and to enhance the performance of the inner loop. The effectiveness of the approach is illustrated by means of a simulation and an experimental example. Practical implementation issues are also discussed.
Motivation & Objective
- To address the limitations of existing direct data-driven LPV control methods that cannot handle input/output constraints.
- To reduce the sensitivity of controller design to the choice of a reference model by decoupling model matching from desired performance.
- To enable practical implementation of data-driven control for real-world LPV systems with measurable scheduling variables and physical constraints.
- To demonstrate the effectiveness of the approach on both simulated and experimental LPV systems, including a switching RC circuit.
- To provide a framework that remains fully data-driven, without requiring a priori knowledge of the plant model.
Proposed method
- The control architecture consists of an inner LPV controller designed via direct data-driven identification to match a first-order reference model, ensuring robustness and simplicity.
- The inner controller uses a first-order LPV structure with integral action and static dependence on the scheduling signal, with parameters identified using kernel-based regularization.
- An outer MPC-based controller acts as a reference governor, manipulating the reference signal to enforce constraints on input (0–5 V) and output (0–5 V) voltages.
- The MPC uses a prediction horizon of 3, control horizon of 3, and tuning weights Qy=0.45, Qg=0.1, with no input rate or control cost penalties.
- The entire design procedure is data-driven, relying only on input-output data from open-loop experiments, without requiring system model identification.
- Hyper-parameters (γ=1000, σ=1) are tuned via cross-validation on a separate data set to ensure generalization.
Experimental results
Research questions
- RQ1Can a direct data-driven control method for LPV systems effectively handle input and output constraints without relying on a priori system modeling?
- RQ2Does decoupling the reference model choice from the desired closed-loop behavior improve robustness and practicality in data-driven LPV control?
- RQ3How does the hierarchical architecture of an inner LPV controller and outer MPC improve performance compared to a standalone data-driven controller?
- RQ4Can the proposed method be effectively implemented in real-time on embedded hardware with limited computational resources?
- RQ5What is the impact of load switching on closed-loop stability and tracking performance in a real-world LPV system?
Key findings
- The proposed hierarchical controller achieved faster rise times and better tracking performance than the inner LPV controller alone, with the outer MPC significantly improving transient response.
- The controlled output voltage remained within the 0–5 V range, and the input voltage was constrained to the same range, satisfying hardware limitations of the Arduino microcontroller.
- The MPC computation time ranged from 9 ms to 19 ms per sample, well below the 150 ms sampling time, enabling real-time implementation.
- The system exhibited only negligible oscillations (less than 0.1 V) during load switching events at τ≈90 s and τ≈320 s, indicating robustness to disturbances.
- The method outperformed the direct data-driven approach of [9] in both simulation and experimental settings, particularly in constraint handling and dynamic response.
- The use of a simple reference model for the inner loop reduced model uncertainty and complexity, while the outer MPC ensured constraint satisfaction and enhanced performance.