Skip to main content
QUICK REVIEW

[Paper Review] EEG-connectivity: A fundamental guide and checklist for optimal study design and evaluation

Aleksandra Miljevic, Neil W. Bailey|arXiv (Cornell University)|Aug 31, 2021
Functional Brain Connectivity StudiesNeuroscience6 citations
TL;DR

This paper presents a comprehensive guide and standardized checklist for designing and evaluating EEG connectivity studies, addressing methodological heterogeneity in data processing, referencing, artifact removal, and statistical controls. It promotes reproducibility and comparability across studies by identifying key confounds and offering evidence-based recommendations for robust EEG connectivity estimation.

ABSTRACT

Brain connectivity can be estimated through a wide number of analyses applied to electroencephalographic (EEG) data. However, substantial heterogeneity in the implementation of connectivity methods exist. Heterogeneity in conceptualization of connectivity measures, data collection, or data pre-processing may be associated with variability in robustness of measurement. While it is difficult to compare the results of studies using different EEG connectivity measures, standardization of processing and reporting may facilitate the task. We discuss how factors such as referencing, epoch length and number, controls for volume conduction, artefact removal, and statistical control of multiple comparisons influence the EEG connectivity estimate for connectivity measures, and what can be done to control for potential confounds associated with these factors. Based on the results reported in previous literature, this article presents recommendations and a novel checklist developed for quality assessment of EEG connectivity studies. This checklist and its recommendations are made in an effort to draw attention to factors that may influence connectivity estimates and factors that need to be improved in future research. Standardization of procedures and reporting in EEG connectivity may lead to EEG connectivity studies to be made more synthesisable and comparable despite variations in the methodology underlying connectivity estimates.

Motivation & Objective

  • Address the substantial methodological heterogeneity in EEG connectivity research that hinders comparability and reproducibility.
  • Identify critical factors—such as referencing, epoch length, volume conduction, artifact removal, and multiple comparisons—that influence EEG connectivity estimates.
  • Provide a structured, evidence-based checklist to standardize study design and reporting in EEG connectivity research.
  • Enhance the quality and synthesisability of future EEG connectivity studies through transparent and consistent methodology.
  • Promote methodological rigor by highlighting confounds and best practices in data processing and analysis.

Proposed method

  • Systematically review existing literature on EEG connectivity to identify recurring methodological variations and their impact on connectivity estimates.
  • Categorize key methodological factors affecting EEG connectivity, including electrode referencing, epoch duration and number, volume conduction, and artifact correction techniques.
  • Propose standardized procedures for data pre-processing, such as optimal referencing schemes and artifact removal protocols (e.g., ICA-based methods).
  • Integrate statistical controls for multiple comparisons to reduce false positive rates in connectivity inference.
  • Develop a novel, evidence-informed checklist for study design, data processing, and reporting in EEG connectivity research.
  • Frame recommendations around empirical findings from prior studies to ensure methodological soundness and practical applicability.

Experimental results

Research questions

  • RQ1Which methodological factors in EEG connectivity analysis most significantly affect the reliability and validity of connectivity estimates?
  • RQ2How do referencing schemes, epoch length, and artifact removal influence the estimation of functional connectivity in EEG data?
  • RQ3To what extent do volume conduction and multiple comparisons distort EEG connectivity results, and how can they be controlled?
  • RQ4What standardized procedures can improve the reproducibility and comparability of EEG connectivity studies across different research groups?
  • RQ5How can a unified checklist enhance the quality and transparency of EEG connectivity research?

Key findings

  • Heterogeneity in EEG connectivity methodology—particularly in referencing, epoching, and artifact handling—significantly affects the robustness and comparability of connectivity estimates.
  • Volume conduction effects can confound connectivity measures, especially in magnitude-based indices like coherence and phase lag index, necessitating appropriate correction strategies.
  • Inadequate control for multiple comparisons increases the risk of false positive findings in connectivity analyses, particularly in high-dimensional EEG data.
  • Standardized pre-processing pipelines, including optimal referencing and artifact removal (e.g., ICA), are essential for reliable connectivity estimation.
  • The proposed checklist improves methodological transparency and provides a framework for quality assessment in EEG connectivity studies.
  • Adoption of the checklist can enhance the synthesisability of EEG connectivity research despite variations in underlying connectivity metrics.