[Paper Review] Evolution of the Milky Way in Semi-Analytic Models: Detecting Cold Gas at z=3 with ALMA and SKA
This study uses the S3-SAX semi-analytic galaxy model to forecast ALMA and SKA capabilities for detecting cold gas in Milky Way progenitors at z=3. It finds that ALMA can detect CO(3–2) in ~50% of MW progenitors within 24 hours, while SKA's high-frequency array will detect nearly all such galaxies via CO(1–0), making it far more effective for blind surveys, though HI detection remains infeasible for individual MW analogs with SKA-Low.
We forecast the abilities of the Atacama Large Millimeter/submillimeter Array (ALMA) and the Square Kilometer Array (SKA) to detect CO and HI emission lines in galaxies at redshift z=3. A particular focus is set on Milky Way (MW) progenitors at z=3 for their detection within 24 h constitutes a key science goal of ALMA. The analysis relies on a semi-analytic model, which permits the construction of a MW progenitor sample by backtracking the cosmic history of all simulated present-day galaxies similar to the real MW. Results: (i) ALMA can best observe a MW at z=3 by looking at CO(3-2) emission. The probability of detecting a random model MW at 3-sigma in 24 h using 75 km/s channels is roughly 50%, and these odds can be increased by co-adding the CO(3-2) and CO(4-3) lines. These lines fall into ALMA band 3, which therefore represents the optimal choice towards MW detections at z=3. (ii) Higher CO transitions contained in the ALMA bands geq6 will be invisible, unless the considered MW progenitor coincidentally hosts a major starburst or an active black hole. (iii) The high-frequency array of SKA, fitted with 28.8 GHz receivers, would be a powerful instrument for observing CO(1-0) at z=3, able to detect nearly all simulated MWs in 24 h. (iv) HI detections in MWs at z=3 using the low-frequency array of SKA will be impossible in any reasonable observing time. (v) SKA will nonetheless be a supreme ha survey instrument through its enormous instantaneous field-of-view (FoV). A one year pointed HI survey with an assumed FoV of 410 sqdeg would reveal at least 10^5 galaxies at z=2.95-3.05. (vi) If the positions and redshifts of those galaxies are known from an optical/infrared spectroscopic survey, stacking allows the detection of HI at z=3 in less than 24 h.
Motivation & Objective
- To assess the detectability of cold gas (CO and HI) in Milky Way progenitors at z=3 using ALMA and SKA.
- To evaluate the feasibility of the ALMA science goal: detecting CO or CII emission in a MW-like galaxy at z=3 within 24 hours.
- To compare the performance of ALMA and SKA in targeted versus blind surveys of high-redshift galaxies.
- To determine optimal observing bands and strategies for detecting molecular and atomic gas in distant galaxies.
- To provide a statistical framework for comparing future cold gas surveys with cosmological simulations.
Proposed method
- The S3-SAX semi-analytic model simulates the cosmic evolution of HI and H2 in galaxies, including MW-type systems, backtracking to z=3.
- Galaxy properties such as CO luminosities and HI masses are derived from the model's star formation and metallicity histories.
- Observing conditions for ALMA and SKA are modeled using instrument specifications: frequency bands, beam sizes, integration times, and sensitivity curves.
- Detection probabilities are calculated using signal-to-noise ratios (S/N) at 3σ significance over 24-hour integrations.
- Stacking techniques are evaluated for HI detection when source positions and redshifts are known from prior optical/infrared surveys.
- Sensitivity comparisons are made between ALMA and SKA across different frequency bands and observing modes (e.g., SKA-HF, SKA-LF, SKA-MF).
Experimental results
Research questions
- RQ1Can ALMA detect CO(3–2) emission from Milky Way progenitors at z=3 within a 24-hour observation?
- RQ2How does the performance of ALMA compare to SKA in detecting CO and HI lines at z=3?
- RQ3What are the optimal observing bands and line transitions for detecting cold gas in high-redshift MW analogs?
- RQ4Can stacking techniques enable HI detection in MW progenitors at z=3 using SKA if source positions are known?
- RQ5How many galaxies can SKA-Low detect in a blind HI survey at z=3, and how does this compare to ALMA’s CO survey capabilities?
Key findings
- ALMA can detect CO(3–2) emission from Milky Way progenitors at z=3 with approximately 50% probability in 24 hours using 75 km s⁻¹ channels.
- Co-adding CO(3–2) and CO(4–3) lines increases detection probability, with ALMA band 3 being optimal for MW detection at z=3.
- Higher CO transitions (bands ≥6) are undetectable with ALMA unless the galaxy hosts a starburst or active nucleus.
- SKA’s high-frequency array (SKA-HF) can detect nearly all simulated MW progenitors via CO(1–0) in 24 hours due to its 1000× larger collecting area and wider field of view.
- HI detection in individual MW progenitors at z=3 is unfeasible with SKA-Low, requiring over 40,000 hours of integration time for 3σ detection.
- A one-year pointed HI survey with SKA-Low’s 410 deg² field of view would detect at least 10⁵ galaxies at z=2.95–3.05, far exceeding ALMA’s CO survey capacity.
Read this paper
Open the full text in the Nubint reader and ask about any passage as you read.
Read this paper on NubintThis review was generated by AI from the original paper. Please check the paper before citing it.