TL;DR

This paper proposes a random lasing-based pH sensor using a self-assembled inverse silk photonic glass with Rhodamine-6G dye, where lasing threshold shifts due to pH-induced changes in gain and quantum efficiency. The mechanism achieves up to 200-fold higher sensitivity than conventional fluorescence sensing, validated by a dispersive diffusive lasing model matching experimental data with no free parameters.

ABSTRACT

Here we report a random lasing based sensor which shows pH sensitivity exceeding by 2-orders of magnitude that of a conventional fluorescence sensor. We explain the sensing mechanism as related to gain modifications and lasing threshold nonlinearities. A dispersive diffusive lasing theory matches well the experimental results, and allow us to predict the optimal sensing conditions and a maximal sensitivity as large as 200 times that of an identical fluorescence-based sensor. The simplicity of operation and high sensitivity make it promising for future biosensing applications.

Motivation & Objective

  • To develop a highly sensitive, biocompatible biosensor using random lasing for biochemical detection.
  • To understand and explain the sensing mechanism in random lasing systems, particularly the role of gain and threshold nonlinearities.
  • To demonstrate that random lasing can outperform fluorescence sensing in sensitivity by exploiting stimulated emission and nonlinear dynamics.
  • To predict optimal sensing conditions and maximal sensitivity using a theoretical model without free parameters.
  • To explore the feasibility of using random lasing for in vivo and implantable biosensing applications.

Proposed method

  • Fabrication of a self-assembled inverse silk photonic glass with embedded Rhodamine-6G dye to create a disordered gain medium.
  • Use of nanosecond pulsed Nd:YAG laser (532 nm, 840 µJ/mm²) to excite the system above the lasing threshold.
  • Systematic variation of pH via NaOH concentration to probe lasing and fluorescence emission changes.
  • Measurement of emission spectra, peak intensity, and full width at half maximum (FWHM) to track lasing suppression at high pH.
  • Application of a dispersive diffusive lasing model based on light diffusion and classical rate equations with spectral mode competition.
  • Sensitivity analysis of key parameters (σₐ, τ, Φ, σₑ) to identify the most responsive variables for sensing.

Experimental results

Research questions

  • RQ1How does pH variation affect the lasing threshold and emission characteristics in a random lasing system?
  • RQ2What is the dominant physical mechanism behind the enhanced sensitivity in random lasing compared to fluorescence?
  • RQ3Can a theoretical model without free parameters accurately predict the experimental sensing response?
  • RQ4Which material or optical parameter (gain, quantum yield, lifetime, etc.) contributes most to sensitivity enhancement?
  • RQ5What are the optimal operating conditions and limit of detection for pH sensing in this random lasing architecture?

Key findings

  • The random lasing sensor exhibits a 100-fold decrease in peak intensity and a sharp increase in FWHM from 14 nm to 54 nm as pH increases from 7 to 13, indicating lasing suppression.
  • The experimental sensitivity reaches S_pH = 200 ± 50 at pH = 13, exceeding the theoretical prediction of ~60 and surpassing conventional fluorescence by two orders of magnitude.
  • The sensitivity peaks around the lasing threshold, with quantum efficiency (Φ) showing the highest sensitivity (S_Φ = 201) due to the transition from spontaneous to stimulated emission.
  • Gain coefficient (σₑ) is the most sensitive parameter, with S_σₑ = 186, and a 10% reduction in σₑ suppresses lasing entirely.
  • The limit of detection (LOD) for pH is estimated at 0.03 in the pH 12–13 range, defined as 3 times the signal-to-noise ratio.
  • The dispersive diffusive lasing model accurately predicts the experimental behavior without free parameters, confirming the role of gain and threshold nonlinearities in the sensing mechanism.