Skip to main content
QUICK REVIEW

[Paper Review] FlatCam: Thin, Bare-Sensor Cameras using Coded Aperture and Computation

M. Salman Asif, Ali Ayremlou|arXiv (Cornell University)|Sep 1, 2015
Optical measurement and interference techniquesComputer Science33 references67 citations
TL;DR

FlatCam proposes a thin, lensless camera using a coded aperture mask placed millimeters above a bare image sensor, where each sensor pixel records a linear combination of scene light. Computational reconstruction via inverse problem solving enables image recovery, achieving ~100x higher light collection than equivalent-thickness lens-based cameras due to large sensor area and optimized mask design.

ABSTRACT

FlatCam is a thin form-factor lensless camera that consists of a coded mask placed on top of a bare, conventional sensor array. Unlike a traditional, lens-based camera where an image of the scene is directly recorded on the sensor pixels, each pixel in FlatCam records a linear combination of light from multiple scene elements. A computational algorithm is then used to demultiplex the recorded measurements and reconstruct an image of the scene. FlatCam is an instance of a coded aperture imaging system; however, unlike the vast majority of related work, we place the coded mask extremely close to the image sensor that can enable a thin system. We employ a separable mask to ensure that both calibration and image reconstruction are scalable in terms of memory requirements and computational complexity. We demonstrate the potential of the FlatCam design using two prototypes: one at visible wavelengths and one at infrared wavelengths.

Motivation & Objective

  • Address the challenge of miniaturizing cameras while preserving light collection, as traditional lens-based designs suffer from reduced aperture and light throughput at small scales.
  • Overcome the trade-off between thin form factor and image quality by replacing lenses with a coded mask near the sensor.
  • Enable high light collection in thin devices by maximizing sensor area and using a separable mask to reduce computational complexity.
  • Demonstrate feasibility through visible and infrared prototypes with near real-time reconstruction.
  • Achieve superior light collection efficiency compared to miniature lens-based cameras by decoupling thickness from aperture size.

Proposed method

  • Use a binary, coded mask placed 0.5mm above a conventional image sensor to modulate light from the scene, creating a multiplexed measurement on the sensor.
  • Model the sensor response as a linear system where each pixel integrates light through the mask pattern, represented by a linear operator H.
  • Employ a separable mask design to ensure scalability in memory and computation for calibration and reconstruction.
  • Apply singular value decomposition (SVD) to solve the inverse problem and reconstruct the scene from multiplexed sensor measurements.
  • Use off-the-shelf sensors and masks, with the mask fabricated on a separate wafer bonded to the sensor for manufacturability.
  • Optimize mask patterns to minimize noise amplification during reconstruction and improve spatial resolution.

Experimental results

Research questions

  • RQ1Can a lensless camera achieve high light collection while maintaining a thin profile by replacing optics with a coded aperture near the sensor?
  • RQ2How does the distance between the coded mask and sensor affect angular and spatial resolution in a lensless imaging system?
  • RQ3To what extent can computational reconstruction compensate for the loss of spatial resolution in a multiplexed, coded aperture imaging system?
  • RQ4Can separable mask designs enable scalable calibration and reconstruction for large sensor arrays in lensless cameras?
  • RQ5What is the achievable light collection advantage of FlatCam over traditional miniature lens-based cameras of the same thickness?

Key findings

  • FlatCam prototypes achieve approximately 100x higher light collection than equivalent-thickness lens-based cameras due to a large sensor area and a mask that maintains high effective numerical aperture.
  • The visible prototype operates at near real-time with ~10 fps reconstruction, introducing a ~100 ms delay between capture and display.
  • The TWR (thickness-to-width ratio) of the visible prototype is ~0.075, significantly lower than typical lens-based cameras, enabling superior light collection.
  • The use of a separable mask ensures scalable calibration and reconstruction, reducing memory and computational complexity.
  • Noise amplification in reconstruction is inherent but controllable through careful mask pattern design, though higher spatial frequencies remain limited by the condition number of the linear system.
  • The system demonstrates feasibility in both visible and short-wave infrared (SWIR) wavelengths, with a 5mm mask-sensor spacing in the SWIR prototype.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.