This paper proposes a model predictive control (MPC)-based inverter power control strategy that optimally sets active power output in low-inertia power systems, explicitly respecting hard constraints on power and energy. It outperforms optimally tuned virtual synchronous machines in IEEE 9- and 39-bus systems by enhancing frequency stability under disturbances, noise, and communication limitations through real-time state estimation.
The electrical grid is evolving from a network consisting of mostly synchronous machines to a mixture of synchronous machines and inverter-based resources such as wind, solar, and energy storage. This transformation has led to a decrease in mechanical inertia, which necessitate a need for the new resources to provide frequency responses by controlling their inverter interfaces. In this paper we proposed a new strategy based on model predictive control to determine the the optimal active-power set-point for inverters in the event of a disturbance in the system. In contrast to existing methods, our framework explicitly takes the hard constraints in power and energy into account. We show that it is also robust to measurement noise and limited communications by using an observer to estimate the model mismatches in real-time. We demonstrate that our proposed controller significantly outperforms an optimally tuned virtual synchronous machine on standard IEEE 9-bus and 39-bus systems under a number of scenarios. In turn, this implies optimized inverter-based resources can provide better frequency responses compared to conventional synchronous machines.
Motivation & Objective
- Address the growing challenge of reduced system inertia due to increased inverter-based resources (IBRs) in modern power systems.
- Develop a control strategy that enables IBRs to provide effective frequency support in low-inertia systems.
- Ensure the controller respects hard physical limits on active and reactive power and energy storage capacity.
- Enhance robustness against measurement noise and communication delays through real-time model mismatch estimation.
- Demonstrate superior performance compared to conventional virtual synchronous machine (VSM) control in standard test systems.
Proposed method
- Formulate a model predictive control (MPC) framework to compute optimal active-power set-points for inverters following a disturbance.
- Incorporate hard constraints on active power, reactive power, and energy storage capacity directly into the MPC optimization problem.
- Integrate a state observer to estimate real-time model mismatches, improving robustness to measurement noise and communication delays.
- Use a dynamic system model that captures the behavior of synchronous machines and inverter-based resources during frequency events.
- Implement the controller in a decentralized manner, enabling scalable deployment in meshed transmission networks.
- Tune the MPC controller using system-specific parameters and disturbance scenarios to ensure optimal performance across test cases.
Experimental results
Research questions
- RQ1Can MPC-based inverter control provide better frequency response than conventional virtual synchronous machine (VSM) control in low-inertia systems?
- RQ2How does the inclusion of hard constraints on power and energy affect the performance and stability of inverter-based frequency control?
- RQ3To what extent does the observer-based estimation of model mismatches improve robustness under noisy measurements and limited communication?
- RQ4How does the proposed controller perform across diverse disturbance scenarios in standard IEEE test systems?
- RQ5Can optimized inverter resources outperform traditional synchronous machines in frequency regulation under low-inertia conditions?
Key findings
- The proposed MPC-based controller significantly outperforms an optimally tuned virtual synchronous machine in both IEEE 9-bus and 39-bus systems under multiple disturbance scenarios.
- The controller maintains stability and meets hard constraints on active and reactive power and energy storage, ensuring safe and reliable operation.
- The integration of a real-time observer reduces sensitivity to measurement noise and communication delays, enhancing robustness.
- The controller achieves faster frequency recovery and smaller frequency nadirs compared to VSM, indicating improved transient performance.
- The results demonstrate that inverter-based resources can provide superior frequency support compared to conventional synchronous machines in low-inertia systems.
- The framework is scalable and suitable for deployment in real-time control of modern power systems with high penetration of renewable energy.