Skip to main content
QUICK REVIEW

[Paper Review] Full-response characterization of afterpulsing in single-photon detectors

D. B. Horoshko, V. N. Chizhevsky|arXiv (Cornell University)|Sep 23, 2014
Quantum Information and CryptographyComputer Science3 references4 citations
TL;DR

This paper presents a full-response characterization of afterpulsing in free-running silicon single-photon detectors by fitting the distribution of afterpulse waiting times to a sum of exponentials and a continuous limit with uniform density. The continuous limit provides excellent fitting across the full response function, offering a more physically meaningful model than multiple discrete exponentials.

ABSTRACT

We have performed a statistical characterization of the effect of afterpulsing in a free-running silicon single-photon detector by measuring the distribution of afterpulse waiting times in response to pulsed illumination and fitting it by a sum of exponentials. We show that a high degree of goodness of fit can be obtained for 5 exponentials, but the physical meaning of estimated characteristic times is dubious. We show that a continuous limit of the sum of exponentials with a uniform density between the limiting times gives excellent fitting results in the full range of the detector response function.

Motivation & Objective

  • To statistically characterize afterpulsing in free-running silicon single-photon detectors.
  • To determine whether a sum of exponentials or a continuous limit provides a better fit to measured afterpulse waiting time distributions.
  • To assess the physical interpretability of characteristic times derived from exponential fits.
  • To develop a more accurate and physically meaningful model of afterpulse response for single-photon detectors.

Proposed method

  • Pulsed illumination was used to trigger single-photon events and record afterpulse waiting times.
  • The waiting time distribution was fitted using a sum of five exponential functions.
  • A continuous limit was derived by modeling the sum of exponentials as a uniform density function between minimum and maximum characteristic times.
  • The goodness of fit was evaluated across the entire detector response function.
  • The continuous limit was compared to the discrete exponential sum in terms of fit quality and physical plausibility.

Experimental results

Research questions

  • RQ1Can a sum of five exponentials provide a good fit to the afterpulse waiting time distribution in a free-running silicon single-photon detector?
  • RQ2Do the characteristic times obtained from the exponential fit have clear physical meaning?
  • RQ3Does a continuous limit of the exponential sum with uniform density offer superior fitting performance and physical interpretability?
  • RQ4How does the continuous limit compare to discrete exponential fitting across the full response function?

Key findings

  • A sum of five exponentials provided a high degree of goodness of fit to the measured afterpulse waiting time distribution.
  • The physical interpretation of the individual characteristic times in the five-exponential fit was found to be dubious.
  • The continuous limit of the sum of exponentials with uniform density between limiting times provided excellent fitting results across the full range of the detector response function.
  • The continuous limit model outperformed the discrete exponential model in terms of physical plausibility while maintaining high fitting accuracy.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.