Skip to main content
QUICK REVIEW

[Paper Review] Generic machine identification and maximum efficiency operation of induction machines

Julian Kullick, Christoph M. Hackl|arXiv (Cornell University)|Dec 6, 2018
Electric Motor Design and AnalysisEngineering14 references5 citations
TL;DR

This paper presents a generic, experiment-based method for identifying induction machine parameters in the rotor flux-oriented dq-reference frame, enabling the creation of maximum efficiency per torque (MEPT) lookup tables without requiring explicit iron loss models. The approach captures nonlinearities like saturation and iron losses implicitly through steady-state measurements, achieving superior efficiency over V/Hz and standard field-oriented control, even without torque sensors.

ABSTRACT

This paper proposes an advanced machine identification method for inverter fed squirrel-cage induction machines, based on steady-state measurements in the rotor flux oriented dq-reference frame. The measured machine maps are used to extract maximum efficiency per torque (MEPT) look-up tables, which guarantee the maximum achievable efficiency in every operating point. Furthermore, it is shown, that comparable results can be achieved, even without a torque sensor. The main advantage of the described method is its generality, which implicitly covers magnetic saturation, iron losses and other nonlinear effects that are typically neglected or approximated by complex models. Finally, the efficiencies of V/Hz and field-oriented control (FOC) are calculated for different speeds and load torques, allowing for quantitative assessment and comparison of both methods.

Motivation & Objective

  • To develop a generic, measurement-based method for identifying induction machine parameters under steady-state conditions in the dq-reference frame.
  • To extract maximum efficiency per torque (MEPT) lookup tables that guarantee optimal efficiency across all operating points.
  • To enable efficiency optimization without relying on complex analytical iron loss models or torque sensors.
  • To quantitatively compare the efficiency of V/Hz control and field-oriented control (FOC) across various speeds and load torques.
  • To implicitly capture nonlinear effects such as magnetic saturation and iron losses through experimental data rather than theoretical modeling.

Proposed method

  • Conduct steady-state measurements on a squirrel-cage induction machine using a regular grid of stator current references in the dq-reference frame, covering the feasible current range.
  • Sweep through current points with a 2-second hold at each to ensure steady-state operation, recording voltages, currents, flux linkages, and speeds.
  • Use digital low-pass filtering and mean-value computation to extract steady-state data, followed by symmetry-based expansion to all four quadrants.
  • Apply loess curve fitting in MATLAB to smooth the 3D nonlinear flux and efficiency maps derived from the measurements.
  • Construct MEPT lookup tables from the measured maps by identifying the current combination that minimizes losses for each torque and speed point.
  • Repeat measurements at multiple speeds to create multi-dimensional LUTs for variable-speed operation.

Experimental results

Research questions

  • RQ1Can a generic, experiment-based method identify induction machine parameters in the dq-reference frame without relying on analytical iron loss models?
  • RQ2To what extent can nonlinear effects such as magnetic saturation and iron losses be captured implicitly through steady-state measurements?
  • RQ3How does the efficiency of V/Hz control compare quantitatively to field-oriented control (FOC) across different speeds and load torques?
  • RQ4Can maximum efficiency per torque (MEPT) operation be achieved without a torque sensor, using only stator current and voltage measurements?
  • RQ5What is the achievable efficiency improvement of MEPT control over conventional MTPA and constant flux FOC strategies?

Key findings

  • The proposed method successfully captures nonlinearities such as magnetic saturation and iron losses implicitly through experimental data, without requiring explicit modeling.
  • MEPT lookup tables were generated from measured flux and efficiency maps, enabling optimal current references for maximum efficiency at every operating point.
  • The method achieves comparable results even without a torque sensor, demonstrating the feasibility of sensorless MEPT operation.
  • Field-oriented control (FOC) was shown to be significantly more efficient than V/Hz control across all tested speeds and load conditions.
  • The study provides the first quantitative comparison of V/Hz and FOC efficiency, revealing that FOC's efficiency advantage is often overlooked.
  • The method implicitly accounts for speed-dependent iron losses and main inductance variations due to saturation, which are typically neglected in standard control models.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.