[Paper Review] Geodesic Density Regression for Correcting 4DCT Pulmonary Respiratory Motion Artifacts

Wei Shao, Yue Pan|arXiv (Cornell University)|Jun 12, 2021
Medical Imaging Techniques and ApplicationsMedicine47 references5 citations
TL;DR

This paper proposes Geodesic Density Regression (GDR), a novel algorithm that corrects respiratory motion artifacts in 4DCT lung scans by estimating a smooth, dense 4D deformation field and an artifact-free lung template using tissue density changes and binary artifact masks. GDR outperforms state-of-the-art geodesic intensity regression (GIR) by producing sharper templates, more accurate Jacobian images, and greater robustness to data dropout in both simulated and clinical 4DCT scans.

ABSTRACT

Pulmonary respiratory motion artifacts are common in four-dimensional computed tomography (4DCT) of lungs and are caused by missing, duplicated, and misaligned image data. This paper presents a geodesic density regression (GDR) algorithm to correct motion artifacts in 4DCT by correcting artifacts in one breathing phase with artifact-free data from corresponding regions of other breathing phases. The GDR algorithm estimates an artifact-free lung template image and a smooth, dense, 4D (space plus time) vector field that deforms the template image to each breathing phase to produce an artifact-free 4DCT scan. Correspondences are estimated by accounting for the local tissue density change associated with air entering and leaving the lungs, and using binary artifact masks to exclude regions with artifacts from image regression. The artifact-free lung template image is generated by mapping the artifact-free regions of each phase volume to a common reference coordinate system using the estimated correspondences and then averaging. This procedure generates a fixed view of the lung with an improved signal-to-noise ratio. The GDR algorithm was evaluated and compared to a state-of-the-art geodesic intensity regression (GIR) algorithm using simulated CT time-series and 4DCT scans with clinically observed motion artifacts. The simulation shows that the GDR algorithm has achieved significantly more accurate Jacobian images and sharper template images, and is less sensitive to data dropout than the GIR algorithm. We also demonstrate that the GDR algorithm is more effective than the GIR algorithm for removing clinically observed motion artifacts in treatment planning 4DCT scans. Our code is freely available at https://github.com/Wei-Shao-Reg/GDR.

Motivation & Objective

  • To address motion artifacts in 4DCT scans caused by irregular breathing, which degrade radiation therapy planning.
  • To develop a method that corrects artifacts by leveraging artifact-free regions across multiple breathing phases.
  • To improve upon existing geodesic intensity regression (GIR) by incorporating tissue density changes during respiration.
  • To generate a high-fidelity, artifact-free lung template and a smooth 4D deformation field for accurate image registration.
  • To enhance the accuracy of Jacobian images used in functional avoidance radiation therapy.

Proposed method

  • GDR estimates a smooth, dense 4D vector field that deforms a reference template to match each phase of the 4DCT scan.
  • It uses binary artifact masks to exclude regions with motion artifacts during image regression.
  • The algorithm accounts for local tissue density changes due to air inflow/outflow during respiration, improving accuracy over intensity-constant models.
  • An artifact-free lung template is created by mapping artifact-free regions from all phases into a common coordinate system and averaging them.
  • The L-BFGS optimizer is used to minimize the cost function, with descent direction estimated using limited memory updates of position and gradient vectors.
  • A U-net architecture is employed to automatically detect motion artifact regions in 2D CT slices for generating binary artifact masks.

Experimental results

Research questions

  • RQ1Can geodesic density regression (GDR) more accurately correct motion artifacts in 4DCT scans than geodesic intensity regression (GIR)?
  • RQ2How does GDR perform in the presence of data dropout or missing phases in 4DCT scans?
  • RQ3Does incorporating tissue density changes improve the accuracy of the estimated deformation field and template image?
  • RQ4Can GDR produce sharper, more reliable Jacobian images for functional avoidance radiation therapy?
  • RQ5How effective is the U-net-based artifact detection system in identifying motion artifacts across different breathing phases?

Key findings

  • GDR achieved significantly more accurate Jacobian images compared to the GIR algorithm in simulated 4DCT scans.
  • The GDR-generated template images were sharper and had improved signal-to-noise ratio compared to GIR.
  • GDR demonstrated greater robustness to data dropout, maintaining accuracy even when some phases were missing or corrupted.
  • In clinical 4DCT scans with observed motion artifacts, GDR outperformed GIR in artifact removal and image quality restoration.
  • The U-net-based artifact detection system effectively identified artifact regions, enabling accurate exclusion during regression.
  • The GDR algorithm is freely available on GitHub, supporting reproducibility and further research.