This paper proposes a novel gravity-gradient noise (GGN) subtraction method for third-generation underground gravitational-wave detectors using spatial harmonic expansions of seismic fields in homogeneous rock. By modeling seismic displacement via plane-wave and spherical-wave expansions, the authors show that GGN from distant or local sources can be estimated and subtracted using only a few seismometers near the test mass, with numerical validation confirming sub-2% error for sources at least one wavelength from the surface.
In this paper, we develop a new approach to gravity-gradient noise subtraction for underground gravitational-wave detectors in homogeneous rock. The method is based on spatial harmonic expansions of seismic fields. It is shown that gravity-gradient noise produced by seismic fields from distant sources, stationary or non-stationary, can be calculated from seismic data measured locally at the test mass. Furthermore, the formula is applied to seismic fields from stationary local sources. It is found that gravity gradients from these fields can be subtracted using local seismic measurements. The results are confirmed numerically with a finite-element simulation. A new seismic-array design is proposed that provides the additional information about the seismic field required to ensure applicability of the approach to realistic scenarios even with inhomogeneous rock and non-stationary local sources.
Motivation & Objective
- Address the challenge of gravity-gradient noise (GGN) limiting sensitivity in third-generation underground gravitational-wave detectors below 10 Hz.
- Overcome the prior assumption that hundreds of seismometers were needed for GGN subtraction by developing a more efficient method.
- Enable accurate GGN estimation and subtraction using only local seismic measurements at the test mass location.
- Provide a framework applicable to both distant seismic sources and stationary local sources in homogeneous rock media.
- Propose a seismic array design to extend the method to realistic scenarios with inhomogeneous rock and non-stationary sources.
Proposed method
- Model seismic displacement fields using spatial harmonic expansions, specifically plane-wave and spherical-wave decompositions in homogeneous media.
- Apply the dipole approximation (Eq. 2) to compute gravity-gradient perturbations on test masses from seismic fields.
- Derive analytical expressions for gravity gradients from plane waves (Eq. 3) and spherical waves (Eq. 9), using wave number and radial integration.
- Use frequency-domain solutions (Eq. 6) and time-domain approximations (Eq. 9) to estimate GGN from seismic data at the test mass.
- Validate the method numerically using finite-element simulations, comparing estimated GGN with exact solutions.
- Propose a seismic array design including surface and near-source sensors to capture spatial field components for improved modeling in non-ideal conditions.
Experimental results
Research questions
- RQ1Can gravity-gradient noise from distant seismic sources be accurately estimated using only local seismic measurements at the test mass?
- RQ2To what extent can a few seismometers near the test mass suffice to subtract GGN from stationary local sources in homogeneous rock?
- RQ3How accurate is the analytical approximation of gravity gradients from spherical seismic waves (Eq. 9) compared to the exact solution (Eq. 6)?
- RQ4What is the impact of source proximity to the rock surface on the accuracy of GGN estimation, particularly for surface sources?
- RQ5How can a seismic array be designed to extend the applicability of the method to inhomogeneous rock and non-stationary local sources?
Key findings
- Gravity-gradient noise from distant seismic sources can be accurately estimated and subtracted using only local seismic measurements at the test mass, reducing the need for large-scale seismometer arrays.
- For spherical P-waves originating at least one wavelength from the rock surface, the relative error in GGN estimation using the proposed time-domain approximation (Eq. 9) is less than 0.02.
- The relative deviation increases to 0.1 for sources very close to the surface, indicating that surface sources require special treatment.
- Finite-element simulations confirm that the method achieves sub-2% error for sources at least one wavelength from the outer surface, validating the analytical model.
- A surface seismic array is necessary to effectively subtract gravity gradients from strong local surface sources, especially at low frequencies.
- The method remains valid for both stationary and non-stationary sources when combined with a properly designed seismic sensor network, enabling practical implementation in real-world detector environments.