[Paper Review] Highly Sensitive Gamma-Spectrometers of GERDA for Material Screening: Part 2
This paper presents the design, operation, and performance of two ultra-low-background gamma-spectrometers—Corrado (15 m w.e. in Heidelberg) and Ge mpi III (3500 m w.e. in Gran Sasso)—for high-sensitivity material screening in the GERDA neutrinoless double-beta decay experiment. Both spectrometers achieve sensitivities down to ~1 mBq/kg and ~10 μBq/kg, respectively, using radiopure materials, multi-layered shielding, active muon vetoing, and nitrogen flushing to suppress radon and cosmic-ray backgrounds, with Ge mpi III's performance limited by a 207Bi contamination discovered post-commissioning.
The previous article about material screening for GERDA points out the importance of strict material screening and selection for radioimpurities as a key to meet the aspired background levels of the GERDA experiment. This is directly done using low-level gamma-spectroscopy. In order to provide sufficient selective power in the mBq/kg range and below, the employed gamma-spectrometers themselves have to meet strict material requirements, and make use of an elaborate shielding system. This article gives an account of the setup of two such spectrometers. Corrado is located in a depth of 15 m w.e. at the MPI-K in Heidelberg (Germany), GeMPI III is situated at the Gran-Sasso underground laboratory at 3500 m w.e. (Italy). The latter one aims at detecting sample activities of the order ~0.01 mBq/kg, which is the current state-of-the-art level. The applied techniques to meet the respective needs are discussed and demonstrated by experimental results.
Motivation & Objective
- To develop and deploy highly sensitive gamma-spectrometers for low-level material screening in the GERDA experiment to meet stringent background requirements.
- To achieve detection limits of ~1 mBq/kg and ~10 μBq/kg for radioactive impurities in construction and shielding materials.
- To minimize background contributions from cosmic rays, radon, and intrinsic radioactivity through advanced shielding and environmental control.
- To enable pre-selection of ultra-radiopure materials essential for the success of the GERDA experiment.
- To identify and resolve unexpected contamination issues, such as 207Bi, that compromise spectrometer sensitivity.
Proposed method
- The spectrometers use high-purity germanium (HPGe) detectors with coaxial, p-type crystals (930 g, 37% relative efficiency) for high energy resolution and detection efficiency.
- Background suppression is achieved through a combination of passive shielding (electrolytic copper, lead, borated polyethylene) and active muon vetoing.
- Radon background is minimized via continuous nitrogen flushing at slight overpressure in an airtight stainless steel casing with glove ports and airlock systems.
- The sample chamber uses a Marinelli geometry (18 L volume) to maximize detection efficiency for large samples.
- Monte Carlo simulations and x-ray imaging are used to model and optimize the cryostat and shielding geometry.
- Sensitivity is quantified using the formula $ A_{\text{min}} = \frac{\sqrt{B}}{M \cdot \epsilon \cdot t} $, where $ B $ is background, $ M $ is sample mass, $ \epsilon $ is peak efficiency, and $ t $ is measurement time.
Experimental results
Research questions
- RQ1What is the achievable sensitivity of a low-level gamma-spectrometer in shallow underground sites, and can it meet GERDA's material screening requirements?
- RQ2How effective are multi-layered passive shielding and active muon vetoing in reducing background in ultra-sensitive gamma spectrometry?
- RQ3What contamination sources can compromise the performance of high-sensitivity HPGe spectrometers, and how can they be identified and mitigated?
- RQ4Can nitrogen flushing effectively suppress radon-induced background in sample chambers over extended measurement times?
- RQ5Why did the Ge mpi III spectrometer fail to reach its target sensitivity of 10 μBq/kg, and what was the origin of the 207Bi contamination?
Key findings
- The Corrado spectrometer at 15 m w.e. in Heidelberg achieves a sensitivity of ~1 mBq/kg for 228Th, demonstrating that background suppression by a factor of ~1000 is feasible even in shallow underground sites.
- The Ge mpi III spectrometer at 3500 m w.e. was designed to reach a sensitivity of 10 μBq/kg but was compromised by a 207Bi contamination of (3.74 ± 0.39) mBq within the cryostat.
- The 207Bi contamination was traced to cross-contamination from a hydrochloric acid solution containing 207Bi, transferred via contaminated tweezers during cryostat assembly.
- The contamination is located close to the HPGe crystal, as confirmed by unchanging count rates under additional shielding and summation peak analysis.
- A similar 207Bi contamination was later found on the Ge mpi IV cryostat, but at a lower level by a factor of ten, indicating a systemic risk from handling procedures.
- Cleaning procedures, including cryostat etching and methanol baths, were initiated and tested, with results pending at the time of publication.
Read this paper
Open the full text in the Nubint reader and ask about any passage as you read.
Read this paper on NubintThis review was generated by AI from the original paper. Please check the paper before citing it.