QUICK REVIEW
[Paper Review] Hybrid MCP-PMT characterisation on a testbeam with Cherenkov setup
G. Romolini, J. Alozy|arXiv (Cornell University)|Jan 30, 2026
TL;DR
The paper characterises a hybrid MCP-PMT with integrated CMOS readout in a Cherenkov Ring-Imaging setup, demonstrating single-photon detection at ~10^4 gain and a timing resolution around 283 ps (intrinsic).
ABSTRACT
A novel photodetector based on a MCP-PMT vacuum tube with encapsulated CMOS ASIC has been tested at the CERN SPS high energy hadron beam, allowing single photon Cherenkov detection operating at 10$^4$ gain and with timing resolution of about 280~ps.
Motivation & Objective
- Demonstrate single-photon Cherenkov detection with a hybrid MCP-PMT and Timepix4 ASIC readout.
- Validate detector performance against Geant4 simulations for Cherenkov ring imaging.
- Measure Cherenkov ring properties (radius, photon yield) and timing performance in a testbeam environment.
Proposed method
- Use a solid Cherenkov radiator and focusing optics to project Cherenkov rings onto a Timepix4-based DUT (device under test).
- Operate the MCP-PMT at ~2100 V to achieve ~10^4 gain with low-noise charge sharing across pixels.
- Employ a tracking telescope and a secondary timing reference to select valid Cherenkov events and reconstruct ring parameters.
- Perform ring fitting to extract radius and center, comparing data to Geant4-based simulations.
- Estimate timing performance via a ring-based timing difference method using two independent hit subsets and Crystal Ball fitting.

Experimental results
Research questions
- RQ1Can a hybrid MCP-PMT with integrated CMOS readout resolve single-photon Cherenkov rings in a testbeam?
- RQ2Do observed Cherenkov ring radii and photon counts agree with Geant4 simulations for the given optical and detector configuration?
- RQ3What is the achieved timing resolution for the DUT, and what factors limit it at low gain?
- RQ4How does charge sharing across pixels affect timing jitter and apparent ring properties?
Key findings
- Measured Cherenkov ring radius: data R = 8.62 ± 0.01 mm, simulation R_sim = 8.66 ± 0.01 mm.
- Mean detected photons per ring: data 15 ± 1, simulation 13 ± 1.
- Timing resolution from ring-based analysis: σ_timing = 283 ± 7 ps (intrinsic, after dividing by √2).
- Raw timing distribution width: σ_timing = 400 ± 10 ps for the difference distribution; inferred intrinsic ~283 ps due to independent subsets.
- Gain inferred from cluster charge: mean gain ≈ 9.9 × 10^3 e− per cluster; average pixel charge ≈ 2.7 × 10^3 e−.
- Average cluster size: ~3.5 pixels per photon; signal spread contributes to jitter.
- Detector operated reliably for the full 1-week testbeam campaign at low gain (~10^4).

Read this paper
Open the full text in the Nubint reader and ask about any passage as you read.
Read this paper on NubintThis review was generated by AI from the original paper. Please check the paper before citing it.