[Paper Review] Initial observations in X-point target divertor discharges on MAST-U
First high-power (≥3 MW) H-mode experiments on MAST-U in a double-null X-point-target divertor show broadened plasma-neutral interactions, lower target temperatures and heat fluxes, and preliminary improved ELM buffering, indicating added benefits when combining SXD and XPT configurations.
The first high-power (> 3 MW) H-mode experiments using a double-null X-point-target (XPT) divertor configuration have been performed on MAST-U. The XPT geometry is obtained by combining a large strike point radius, similar to the Super-X divertor (SXD), with an additional X-point near the separatrix in the baffled outer divertor chambers and leads to additional exhaust benefits over the SXD. The broader electron density profile near the secondary X-point leads to additional plasma-neutral interactions, evidenced by a broader hydrogenic emission profile, and resulting in larger power and ion sinks. The increase in plasma-neutral interactions also leads to lower target electron temperatures and heat fluxes. These benefits appear to extend to transients, and preliminary evidence of improved ELM buffering in the XPT is presented. These results showcase how multiple alternative divertor configuration strategies can be combined to improve momentum, power, and particle losses, which may be required for the challenging exhaust conditions of future reactors.
Motivation & Objective
- Motivate detachment and exhaust management for future reactors by exploring alternative divertor configurations (ADCs).
- Assess whether combining Super-X (SXD) geometry with an X-point target (XPT) improves detachment access and exhaust losses.
- Quantify changes in divertor plasma state, target heat fluxes, and ELM buffering in XPT versus SXD.
- Investigate how the XPT affects plasma-neutral interactions and overall divertor performance in high-power H-mode discharges.
Proposed method
- Configure MAST-U to create SXD and then XPT divertor geometries in high-power H-mode discharges.
- Use EFIT magnetic reconstructions to locate primary and secondary X-points and compare coil currents between SXD and XPT.
- Characterize divertor states with D_alpha imaging, coherence imaging spectroscopy (CIS) for ne, and Langmuir probes for j_parallel and Te estimates.
- Decompose D_alpha emission into EIE, MAR, MAD, and EIR contributions using a neural-network-based analysis trained on Fulcher, D_alpha, and D_beta data.
- Assess ELM buffering via a target/upstream Fulcher emissivity proxy from UFDS photodiodes during ELMs, and compare against SXD baselines.
- Estimate Te at the target by combining CIS n_e with LP j_perp, or using D_alpha EIR and CIS n_e (PEC_rec based) as cross-checks.
Experimental results
Research questions
- RQ1Does the XPT configuration increase cross-field profile width and the volume available for plasma-neutral interactions compared to SXD?
- RQ2Do XPT discharges exhibit lower target electron temperatures and heat fluxes than SXD under comparable upstream conditions?
- RQ3Is there evidence of improved ELM buffering in XPT relative to SXD, and under what divertor neutral pressures?
- RQ4How does the detachment front location and sensitivity respond to the presence of a secondary X-point near the separatrix?
- RQ5What are the implications of XPT performance for extrapolation to future reactors with challenging exhaust conditions?
Key findings
- XPT broadens the plasma-neutral interaction region and yields a wider ne/D_alpha profile near the secondary X-point, indicating enhanced volumetric exhaust processes.
- Total divertor emission increases in XPT, driven largely by plasma-molecule interactions (MAR/MAD and EIR), with stronger EIR emission near the target at lower divertor neutral pressures.
- Target electron temperatures and peak parallel heat fluxes are lower in XPT than SXD, especially at low divertor neutral pressures, with a convergence of temperatures at higher pressures.
- Peak heat flux is observed near the psi=0.975 flux surface in both SXD and XPT, suggesting possible magnetic-reconstruction limitations rather than physics-dominant changes at the target.
- Preliminary evidence suggests improved ELM buffering in XPT, indicated by more favorable target/upstream Fulcher emission ratios during ELMs, compared to SXD at similar conditions.
- Compared poloidally, XPT and SXD show similar ne profiles when expressed in poloidal distance from the target, implying the poloidal leg length is a main driver of detached-region profiles while XPT adds additional parallel length.
Read this paper
Open the full text in the Nubint reader and ask about any passage as you read.
Read this paper on NubintThis review was generated by AI from the original paper. Please check the paper before citing it.