Skip to main content
QUICK REVIEW

[Paper Review] Interpretable Alzheimer's Disease Classification Via a Contrastive Diffusion Autoencoder

Ayodeji Ijishakin, Ahmed Abdulaal|arXiv (Cornell University)|Jun 5, 2023
AI in cancer detectionComputer Science3 citations
TL;DR

This paper proposes a contrastive diffusion autoencoder (Contrast-DiffAE) for interpretable Alzheimer’s disease classification using similarity to prototypical training images in a disentangled latent space. By combining a diffusion autoencoder with contrastive learning, the model achieves competitive accuracy while providing human-interpretable explanations through visual prototypes, bridging the gap between model performance and clinical trustworthiness in medical imaging.

ABSTRACT

In visual object classification, humans often justify their choices by comparing objects to prototypical examples within that class. We may therefore increase the interpretability of deep learning models by imbuing them with a similar style of reasoning. In this work, we apply this principle by classifying Alzheimer's Disease based on the similarity of images to training examples within the latent space. We use a contrastive loss combined with a diffusion autoencoder backbone, to produce a semantically meaningful latent space, such that neighbouring latents have similar image-level features. We achieve a classification accuracy comparable to black box approaches on a dataset of 2D MRI images, whilst producing human interpretable model explanations. Therefore, this work stands as a contribution to the pertinent development of accurate and interpretable deep learning within medical imaging.

Motivation & Objective

  • To develop a self-explainable deep learning model for Alzheimer’s disease classification that enhances clinical trust through interpretable reasoning.
  • To address the critical gap between high-performing black-box models and their limited clinical adoption due to lack of interpretability.
  • To leverage generative modeling and contrastive learning to create a semantically meaningful latent space where image similarity to prototypes informs classification.
  • To produce visual explanations based on nearest training examples (prototypes), enabling radiologists to validate model decisions.
  • To demonstrate that interpretable models can match the performance of black-box approaches in medical image classification.

Proposed method

  • The model uses a diffusion autoencoder backbone to learn a disentangled, semantically meaningful latent representation of 2D MRI images.
  • A contrastive loss is applied to push similar-class images closer in the latent space and dissimilar-class images apart, enhancing class-specific semantics.
  • Prototypes are defined as the most similar training images to a given input in the latent space, enabling prototype-based classification.
  • Model predictions are made by computing similarity scores between the input’s latent code and the latent codes of training prototypes.
  • Explanations are generated by retrieving and visualizing the nearest prototypes from the training set, providing intuitive, human-readable justifications.
  • The approach avoids blurry reconstructions common in VAE-based prototypes by using full-resolution training images as explanations.

Experimental results

Research questions

  • RQ1Can a contrastive diffusion autoencoder produce a latent space that enables accurate and interpretable Alzheimer’s disease classification?
  • RQ2How does prototype-based reasoning in a generative model’s latent space compare to black-box models in classification accuracy?
  • RQ3Can the model generate human-understandable explanations by retrieving semantically meaningful training examples as prototypes?
  • RQ4Does the use of a diffusion autoencoder improve the quality of latent representations for medical image interpretation compared to standard VAEs?
  • RQ5Can the model’s interpretability be enhanced by leveraging spectral or clustering-based methods to derive diverse prototypes from latent space structure?

Key findings

  • The Contrast-DiffAE model achieves classification accuracy comparable to state-of-the-art black-box models on a 2D MRI dataset for Alzheimer’s disease.
  • The model provides human-interpretable explanations by retrieving and visualizing the nearest training images (prototypes) in the latent space.
  • The use of full-resolution training images as prototypes preserves anatomical details, enhancing clinical interpretability compared to blurry VAE-based prototypes.
  • Contrastive learning in the latent space effectively separates intra-class from inter-class features, improving decision boundary clarity.
  • The model’s latent space captures semantically meaningful factors of variation, enabling meaningful prototype selection based on image-level similarity.
  • The approach demonstrates that self-explainable models can achieve high performance without sacrificing interpretability, supporting clinical deployment.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.