[Paper Review] Is It Reasonable to Substitute Discontinuous SMC by Continuous HOSMC?
This paper investigates whether replacing discontinuous First-Order Sliding-Mode Control (FOSMC) with continuous Super-Twisting Algorithm (STA) reduces chattering in systems with parasitic dynamics. Using Harmonic Balance (HB) analysis and an Averaged Power (AP) criterion, it shows that for any actuator time constant (ATC), there exists a disturbance where FOSMC produces lower chattering than STA; however, for sufficiently small ATC, STA yields lower chattering and AP. Critical ATC values are derived where chattering amplitudes and AP are equal between the two controllers.
Professor Utkin in his discussion paper proposed an example showing that the amplitude of chattering caused by the presence of parasitic dynamics in systems governed by First-Order Sliding-Mode Control (FOSMC) is lower than the obtained using Super-Twisting Algorithm (STA). This example served to motivate this research reconsidering the problem of comparison of chattering magnitude in systems governed by FOSMC that produces a discontinuous control signal and by STA that produces a continuous one, using Harmonic Balance (HB) methodology. With this aim the Averaged Power (AP) criteria for chattering measurements is revisited. The STA gains are redesigned to minimize amplitude or AP of oscillations predicted by HB. The comparison of the chattering produced by FOSMC and STA with redesigned gains is analyzed taking into account their amplitudes, frequencies and values of AP allowing to conclude that: (a) for any value of upperbound of disturbance and Actuator Time Constant (ATC) there exist a bounded disturbance for which the amplitude and AP of chattering produced by FOSMC is lower than the caused by STA; (b) if the upperbound of disturbance and upperbound of time-derivative disturbance are given, then for all sufficiently small values of ATC the amplitude of chattering and AP produced by STA will be smaller than the caused by FOSMC; (c) critical values of ATC are predicted by HB for which the parameters, amplitude of chattering and AP, produced by FOSMC and STA are the same. Also the frequency of self-exited oscillations caused by FOSMC is always grater than the produced by STA.
Motivation & Objective
- To evaluate whether continuous HOSMC (specifically STA) is preferable to discontinuous FOSMC in terms of chattering reduction under parasitic dynamics.
- To resolve a controversy raised by V. Utkin, who observed that STA can sometimes produce higher chattering amplitudes than FOSMC in the presence of actuator dynamics.
- To develop a systematic methodology based on Harmonic Balance (HB) and Averaged Power (AP) to compare chattering magnitude and frequency between FOSMC and STA.
- To redesign STA gains to minimize chattering amplitude and AP, enabling optimal performance in practical systems with limited actuator bandwidth.
Proposed method
- Reformulates Levant's energy-like criterion for Averaged Power (AP) using Harmonic Balance (HB) methodology to estimate chattering amplitude and frequency.
- Applies HB to model the closed-loop system as a perturbed oscillator, approximating the output x(t) as a first harmonic: x(t) = A sin(ωt).
- Derives analytical expressions for chattering amplitude A and AP as functions of actuator time constant (ATC), disturbance bounds (δ, ∆), and controller gains (M, k1, k2).
- Identifies critical ATC values µ* and µ⋆ where chattering amplitude and AP are equal between FOSMC and STA, respectively.
- Redesigns STA gains (k1, k2) to minimize both chattering amplitude and AP using the HB-based AP criterion.
- Validates results via simulation across varying disturbance frequencies and ATC values, comparing FOSMC and STA performance.
Experimental results
Research questions
- RQ1For any given actuator time constant (ATC), does there exist a bounded disturbance for which FOSMC produces lower chattering amplitude than STA, despite STA's continuous control input?
- RQ2Under what conditions on disturbance bounds (δ, ∆) and ATC does STA produce lower chattering amplitude and Averaged Power (AP) than FOSMC?
- RQ3Can critical ATC values be analytically determined where the chattering amplitude and AP of FOSMC and STA are equal?
- RQ4How do the frequency and amplitude of self-excited oscillations differ between FOSMC and STA under parasitic dynamics?
- RQ5Is it possible to redesign STA gains to minimize chattering amplitude and AP, and does this lead to improved performance over FOSMC?
Key findings
- For any value of ATC, there exists a bounded disturbance for which the chattering amplitude and Averaged Power (AP) produced by FOSMC are lower than those produced by STA, confirming Utkin’s hypothesis.
- When the upper bound of disturbance (δ) and its time-derivative (∆) are fixed, and the ATC is sufficiently small (µ → 0), the chattering amplitude and AP of STA are smaller than those of FOSMC.
- Critical ATC values are analytically derived: µ* = 0.125 δ/∆ for equal chattering amplitude, and µ⋆ = 0.1924 δ/∆ for equal Averaged Power.
- The frequency of self-excited oscillations is always higher for FOSMC than for STA, regardless of ATC.
- Simulation results confirm that when ATC > µ*, FOSMC produces lower chattering than STA; when ATC < µ*, the opposite holds, with STA outperforming FOSMC.
- For the example with δ = ∆ = 60, the critical ATC values are µ* = 0.125 and µ⋆ = 0.1768, and simulations show that FOSMC has lower AP than STA only when µ > 0.1768.
Read this paper
Open the full text in the Nubint reader and ask about any passage as you read.
Read this paper on NubintThis review was generated by AI from the original paper. Please check the paper before citing it.