Skip to main content
QUICK REVIEW

[Paper Review] Ladder Fine-tuning approach for SAM integrating complementary network

Shurong Chai, Rahul Kumar Jain|arXiv (Cornell University)|Jun 22, 2023
AI in cancer detectionComputer Science11 citations
TL;DR

The paper proposes integrating a lightweight CNN encoder with SAM and fine-tuning only the CNN and SAM decoder via a Ladder-Side Tuning inspired gate, achieving competitive medical image segmentation with reduced training cost.

ABSTRACT

Recently, foundation models have been introduced demonstrating various tasks in the field of computer vision. These models such as Segment Anything Model (SAM) are generalized models trained using huge datasets. Currently, ongoing research focuses on exploring the effective utilization of these generalized models for specific domains, such as medical imaging. However, in medical imaging, the lack of training samples due to privacy concerns and other factors presents a major challenge for applying these generalized models to medical image segmentation task. To address this issue, the effective fine tuning of these models is crucial to ensure their optimal utilization. In this study, we propose to combine a complementary Convolutional Neural Network (CNN) along with the standard SAM network for medical image segmentation. To reduce the burden of fine tuning large foundation model and implement cost-efficient trainnig scheme, we focus only on fine-tuning the additional CNN network and SAM decoder part. This strategy significantly reduces trainnig time and achieves competitive results on publicly available dataset. The code is available at https://github.com/11yxk/SAM-LST.

Motivation & Objective

  • Motivate effective fine-tuning of the Segment Anything Model (SAM) for medical image segmentation.
  • Introduce a complementary CNN encoder to SAM while freezing SAM's encoder to reduce training cost.
  • Develop a learnable fusion gate to combine SAM and CNN features.
  • Demonstrate competitive segmentation performance on a public multi-organ dataset with reduced training time.

Proposed method

  • Add a lightweight CNN encoder (ResNet18 truncated to 13 layers) as a complementary encoder to SAM.
  • Fuse SAM encoder features and CNN encoder features via a learnable gate alpha (x = alpha * x_sam + (1-alpha) * x_cnn).
  • Keep SAM encoder and prompt encoder frozen; fine-tune only the SAM decoder and the added CNN and decoder components.
  • Train with a combined loss L = (1 - lambda) * CrossEntropy + lambda * Dice, with lambda = 0.8.
  • Use a ViT-B SAM backbone, do not fine-tune the SAM encoder or prompts, fine-tune the output_upscaling of the SAM decoder.

Experimental results

Research questions

  • RQ1How can a supplementary CNN encoder be integrated with SAM for medical image segmentation without full SAM fine-tuning?
  • RQ2Does a learnable fusion gate between SAM and CNN features improve segmentation performance and training efficiency?
  • RQ3What are the trade-offs in accuracy and training cost when using Ladder-Side Tuning inspired fine-tuning for SAM in medical imaging?

Key findings

  • The proposed method achieves 79.45 DSC on the Synapse dataset, with 35.35 mm HD95.
  • Ablation shows CNN-encoder-only and full-SAM-finetuning both underperform compared to the integrated approach.
  • Using the learnable gate yields a 79.45 DSC with reduced training time (30-40% faster than other fine-tuning methods).
  • Directly fine-tuning the entire SAM yields 58.97 Dice; SAM alone yields 1.73 Dice without fine-tuning or prompts, highlighting the need for domain-specific adaptation.
  • The learnable gate parameter stabilizes around 0.44 in the reported setup.
  • The method is cost-effective by avoiding backpropagation through the entire SAM encoder.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.