Skip to main content
QUICK REVIEW

[Paper Review] LAr1-ND: Testing Neutrino Anomalies with Multiple LArTPC Detectors at Fermilab

C. Adams, Constantinos V Andreopoulos|arXiv (Cornell University)|Sep 30, 2013
Particle Detector Development and PerformancePhysics and Astronomy6 citations
TL;DR

LAr1-ND proposes a near detector using liquid argon time projection chambers (LArTPCs) at Fermilab to resolve short-baseline neutrino anomalies, particularly the MiniBooNE low-energy electron excess and potential sterile neutrino oscillations. By measuring unoscillated neutrino fluxes at 100 m, it enables precise interpretation of MicroBooNE signals and provides 5σ sensitivity to νμ disappearance down to a few percent in the Δm² = 1 eV² region.

ABSTRACT

This white paper describes LAr1-ND and the compelling physics it brings first in Phase 1 and next towards the full LAr1 program. In addition, LAr1-ND serves as a key step in the development toward large-scale LArTPC detectors. Its development goals will encompass testing existing and possibly innovative designs for LBNE while at the same time providing a training ground for teams working towards LBNE combining timely neutrino physics with experience in detector development.

Motivation & Objective

  • To resolve the MiniBooNE low-energy νe excess by measuring unoscillated neutrino fluxes with high-precision LArTPC technology.
  • To test the existence of sterile neutrinos via νμ disappearance and neutral-current interactions at short baselines.
  • To provide a critical near detector role for the full LAr1 program, enabling interpretation of MicroBooNE signals and extending sensitivity to antineutrino modes.
  • To serve as a technology development platform for large-scale LArTPC detectors, including future LBNE and DUNE experiments.
  • To enable shape-only sensitivity to νμ disappearance across a broad Δm² range, including the 1 eV² region, with high statistical power.

Proposed method

  • Deploy a single kton-scale LArTPC detector at 100 m from the Booster Neutrino Beam, using high-granularity wire readout for precise energy and track reconstruction.
  • Utilize the detector’s fine sampling and calorimetric capabilities to measure neutrino interactions with high resolution, enabling particle identification and background suppression.
  • Combine data from LAr1-ND with MicroBooNE (at ~300 m) and a future far detector (at ~700 m) to perform a three-point oscillation measurement, constraining systematic uncertainties.
  • Apply shape-only sensitivity analysis to νμ disappearance, leveraging the oscillation probability evolution across three baselines to distinguish new physics from background.
  • Simulate detector response and neutrino fluxes using detailed Monte Carlo methods to predict sensitivity to sterile neutrino models.
  • Use the near detector to measure neutral-current interactions, probing active-to-sterile oscillations independently of charged-current channels.

Experimental results

Research questions

  • RQ1Can LAr1-ND definitively resolve the MiniBooNE low-energy νe excess by measuring the unoscillated neutrino flux with high precision?
  • RQ2What is the sensitivity of the LAr1-ND + MicroBooNE + far detector configuration to νμ disappearance in the 1 eV² sterile neutrino region?
  • RQ3Can the three-detector configuration distinguish oscillation signals from background or new physics using shape-only analysis?
  • RQ4How effective is LAr1-ND in constraining systematic uncertainties in νμ disappearance and appearance measurements?
  • RQ5To what extent can LAr1-ND enable antineutrino mode measurements and future studies of sterile neutrinos in the ν̄μ sector?

Key findings

  • LAr1-ND achieves 5σ sensitivity to νμ disappearance down to a few percent in the Δm² = 1 eV² region, enabling definitive testing of sterile neutrino models.
  • The detector is expected to record over 600,000 neutrino interactions per year, providing high-statistics data for neutrino-argon cross-section measurements.
  • At 100 m baseline, LAr1-ND is optimally positioned to sample the unoscillated neutrino flux before significant oscillation occurs, reducing systematic uncertainty.
  • The three-detector configuration (LAr1-ND, MicroBooNE, and far detector) enables shape-only sensitivity to νμ disappearance that regains significant sensitivity for large Δm² values (≥10 eV²).
  • The LAr1-ND detector provides a critical role in interpreting MicroBooNE signals, whether from electrons or photons, by measuring the initial neutrino flux.
  • The program enables sensitivity to νe appearance in both neutrino and antineutrino modes, extending the reach of the short-baseline neutrino program at Fermilab.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.