This study demonstrates a linear correlation between pre- and post-radiation input bias currents in commercial bipolar devices (MC4741, LM324N, LM2901) under varying gamma-ray doses, dose rates, and temperatures. The correlation arises from radiation-induced space charge region (SCR) current linearly coupling with pre-irradiation diffusion current in the emitter, enabling accurate damage prediction and nondestructive device selection.
Due to variability, the input bias currents in bipolar devices, no matter before or after gamma-ray irradiations, are different for different samples. In this work, we experimentally demonstrate that there is a linear correlation between the pre-radiation and post-radiation input bias currents for samples from the same manufacturer and the same batch. The correlation is found in three typical commercial off-the-shelf (COTS) bipolar devices, including quad-operation amplifiers MC4741, LM324N and quad comparator LM2901, which are irradiated with different gamma ray total doses, dose rates, and temperatures. We indicated that, the possible mechanism of the remarkable effect is that, in the input stage bipolar junction transistor, the radiation-induced space charge region (SCR) current and the pre-radiation carriers diffusion current are generated in the same emitter region thus obey a linear correlation, while the radiation-induced neutral base surface (NBS) current is generated in a different (base) region thus is independent from the diffusion current. Moreover, it is found that, the SCR-like component dominates in MC4741, the NBS-like component dominates in LM324N, while the two components are comparable in LM2901, implying different roles of the two components in the total dose effect of different kind of devices. The found linear correlation can be used in exact damage prediction and nondestructive device selection.
Motivation & Objective
- To investigate the relationship between pre-radiation and post-radiation input bias currents in bipolar devices under gamma irradiation.
- To identify the underlying physical mechanisms responsible for the observed correlation in input bias current behavior.
- To determine how radiation-induced current components (SCR and NBS) contribute differently across device types.
- To enable nondestructive device selection and accurate radiation damage prediction using the observed correlation.
- To quantify the relative dominance of SCR-like and NBS-like current components in different bipolar device models.
Proposed method
- Experimental measurement of input bias currents in three COTS bipolar devices (MC4741, LM324N, LM2901) before and after gamma-ray irradiation.
- Systematic variation of total dose, dose rate, and temperature during irradiation to assess consistency of the correlation.
- Analysis of current components in the input stage: radiation-induced space charge region (SCR) current and neutral base surface (NBS) current.
- Separation of SCR-like and NBS-like current contributions based on their spatial origin (emitter vs. base region) and dependence on pre-irradiation diffusion current.
- Use of linear regression to quantify the correlation between pre- and post-irradiation input bias currents across multiple samples.
- Comparison of relative contributions of SCR and NBS components in different device types based on their current behavior.
Experimental results
Research questions
- RQ1Is there a consistent linear relationship between pre- and post-radiation input bias currents in the same batch of bipolar devices?
- RQ2What physical mechanisms underlie the observed linear correlation in input bias current across irradiated samples?
- RQ3How do radiation-induced space charge region (SCR) and neutral base surface (NBS) currents contribute differently to the total input bias current?
- RQ4To what extent do the SCR-like and NBS-like current components dominate in different bipolar device models?
- RQ5Can the observed linear correlation be used for nondestructive device selection and accurate prediction of radiation-induced damage?
Key findings
- A strong linear correlation was experimentally observed between pre- and post-radiation input bias currents in three COTS bipolar devices across varying irradiation conditions.
- The correlation arises because radiation-induced SCR current in the emitter region is linearly dependent on pre-irradiation diffusion current in the same region.
- The radiation-induced NBS current, generated in the base region, is independent of the pre-irradiation diffusion current.
- In MC4741, the SCR-like component dominates the total input bias current, while in LM324N, the NBS-like component is dominant.
- In LM2901, the SCR-like and NBS-like components are comparable in magnitude, indicating a balanced contribution to the total dose effect.
- The observed linear correlation enables precise prediction of post-irradiation behavior and supports nondestructive device selection in radiation environments.