[Paper Review] Macroscopic quantum test with bulk acoustic wave resonators
This paper demonstrates the most macroscopic quantum test to date using a bulk acoustic wave resonator in a sapphire crystal, achieving a macroscopicity measure of μ = 11.3 by directly measuring Wigner function negativities in a 1 μg mechanical mode. The experiment rules out classical descriptions at the microgram scale and sets bounds on spontaneous collapse models via Bayesian inference on decoherence rates.
Recently, solid-state mechanical resonators have become a platform for demonstrating non-classical behavior of systems involving a truly macroscopic number of particles. Here, we perform the most macroscopic quantum test in a mechanical resonator to date, which probes the validity of quantum mechanics at the microgram mass scale. This is done by a direct measurement of the Wigner function of a high-overtone bulk acoustic wave resonator mode, monitoring the gradual decay of negativities over tens of microseconds. While the obtained macroscopicity of $μ= 11.3$ is on par with state-of-the-art atom interferometers, future improvements of mode geometry and coherence times could confirm the quantum superposition principle at unprecedented scales.
Motivation & Objective
- To test the validity of quantum mechanics against macrorealistic modifications at the microgram mass scale.
- To demonstrate genuine quantum behavior in a mechanical resonator involving ~10^16 atoms in coherent motion.
- To establish a benchmark for macroscopicity using Wigner function negativities and Bayesian inference on decoherence.
- To set improved bounds on spontaneous collapse models (e.g., CSL) using non-interferometric measurements of thermal heating.
- To guide future design of electromechanical systems for testing quantum superposition at even larger scales.
Proposed method
- A superconducting qubit is coupled to a high-overtone bulk acoustic wave mode in a sapphire crystal via a piezoelectric layer, enabling quantum state preparation and readout.
- The Wigner function of the phonon mode is reconstructed using displaced parity measurements performed via the qubit's conditional dynamics.
- Bayesian inference is applied to the measured data to estimate the maximum allowed diffusion rate Γ, which quantifies macrorealistic modifications.
- The macroscopicity μ is derived from the logarithm of the largest excluded coherence time τₑ, based on the inferred Γ.
- The analysis assumes all observed diffusion arises from macrorealistic collapse, providing conservative bounds on τₑ and Γ.
- Theoretical modeling accounts for relaxation (γ↓) and diffusion (Γ) to relate measured thermal population to exclusion limits on collapse models.
Experimental results
Research questions
- RQ1What is the largest macroscopicity μ achieved in a mechanical resonator using nonclassical state signatures?
- RQ2Can Wigner function negativities be observed in a mechanical mode with effective mass of 1 μg and coherence time up to 40 μs?
- RQ3To what extent can spontaneous collapse models be ruled out using non-interferometric measurements of thermal heating in a bulk acoustic resonator?
- RQ4How does the geometry of the resonator influence the potential for future macroscopic quantum tests?
- RQ5Can the macroscopicity measure μ be meaningfully applied to systems with sub-nuclear delocalization of constituent atoms?
Key findings
- The experiment achieves a macroscopicity of μ = 11.3, representing the most macroscopic quantum test in a mechanical resonator to date.
- Wigner function negativities are observed for up to 40 μs in a 1 μg bulk acoustic mode, confirming non-classical behavior.
- The measured relaxation rate γ↓ ≈ 1/T₁ leads to an exclusion of τₑ < 1.9 × 10¹¹ s at a length scale of 5 × 10⁻⁷ m.
- The maximum dimensionless diffusion rate Γ is inferred as 0.016γ↓, consistent with a thermal population of 1.6%.
- Theoretical modeling confirms that the diffusion rate Γ scales with mode geometry and material parameters, enabling optimization for future experiments.
- The results are consistent with a recent proposal for non-interferometric collapse model tests, with exact agreement in the diffusion rate expression for bulk resonators.
Read this paper
Open the full text in the Nubint reader and ask about any passage as you read.
Read this paper on NubintThis review was generated by AI from the original paper. Please check the paper before citing it.