[Paper Review] MAGIC sensitivity to millisecond-duration optical pulses
This study experimentally determines the sensitivity of the MAGIC Cherenkov telescope's central pixel to isolated 1–10 ms optical pulses, achieving a detection threshold of m = 13.5 ± 0.6 in the U band. By slewing the telescope across bright stars and correlating measured voltages with known stellar magnitudes, the method establishes a linear voltage–magnitude response, enabling detection of orphan millisecond optical flashes relevant to Fast Radio Burst (FRB) searches.
The MAGIC telescopes are a system of two Imaging Atmospheric Cherenkov Telescopes (IACTs) designed to observe very high energy (VHE) gamma rays above ~50 GeV. However, as IACTs are sensitive to Cherenkov light in the UV/blue and use photo-detectors with a time response well below the ms scale, MAGIC is also able to perform simultaneous optical observations. Through an alternative system installed in the central PMT of MAGIC II camera, the so-called central pixel, MAGIC is sensitive to short (1ms - 1s) optical pulses. Periodic signals from the Crab pulsar are regularly monitored. Here we report for the first time the experimental determination of the sensitivity of the central pixel to isolated 1-10 ms long optical pulses. The result of this study is relevant for searches of fast transients such as Fast Radio Bursts (FRBs).
Motivation & Objective
- To experimentally determine the sensitivity of the MAGIC central pixel system to isolated millisecond optical pulses.
- To calibrate the voltage response of the central pixel to known optical fluxes from bright stars during telescope slewing.
- To establish a quantitative detection threshold for orphan optical flashes, relevant for Fast Radio Burst (FRB) searches.
- To validate the system’s performance using the well-known Crab pulsar light curve as a reference.
- To enable simultaneous Very High Energy (VHE) gamma-ray and optical time-domain observations with high temporal resolution.
Proposed method
- The central pixel’s DC branch was upgraded to a bandwidth exceeding 3 kHz, allowing detection of fast optical pulses.
- An optical fiber transmission system was implemented to send the central pixel signal from the telescope camera to the counting house.
- A dedicated optical receiver mezzanine board converted the optical signal back to electrical and routed it to both the standard Domino DAQ and a central pixel PC for independent digitization.
- The telescope was slewing at ~4.7 deg/s across the sky, producing 20 ms optical pulses from stars passing through the central pixel field of view.
- Measured pulse amplitudes were correlated with the known magnitudes of stars within the telescope’s point spread function (PSF), using Gaussian smearing to model pulse broadening.
- A linear fit was applied to the voltage–magnitude relation of correlated pulses, and sensitivity was extrapolated to the 5σ noise threshold.
Experimental results
Research questions
- RQ1What is the minimum detectable optical magnitude for a 1 ms isolated flash using the MAGIC central pixel system?
- RQ2How does the central pixel’s voltage response correlate with the known magnitude of bright stars during high-speed slewing?
- RQ3Can the central pixel system reliably distinguish genuine optical pulses from background noise during fast slewing?
- RQ4To what extent does the system’s sensitivity match expectations based on the Crab pulsar light curve?
- RQ5What is the effective bandwidth and timing resolution of the central pixel system for detecting millisecond optical transients?
Key findings
- The central pixel system achieves a sensitivity threshold of m = 13.5 ± 0.6 in the U band for detecting isolated 1 ms optical flashes.
- A linear voltage–magnitude relation was established between measured pulse amplitudes and the known magnitudes of stars passing through the central pixel field of view.
- The system successfully detected optical pulses from stars with durations of ~20 ms due to telescope slewing, confirming the temporal resolution capability.
- The measured sensitivity is consistent with the expected response derived from the Crab pulsar light curve, validating the calibration method.
- The central pixel system can detect VHE gamma-ray and optical transients simultaneously, with sub-millisecond time resolution.
- System instabilities during slewing, particularly in pointing accuracy and PSF, contributed to observed dispersion in the calibration data, but did not invalidate the overall calibration.
Read this paper
Open the full text in the Nubint reader and ask about any passage as you read.
Read this paper on NubintThis review was generated by AI from the original paper. Please check the paper before citing it.