Skip to main content
QUICK REVIEW

[Paper Review] Measurement of the angular resolution of the ARGO-YBJ detector

G. Di Sciascio, E. Rossi|ArXiv.org|Oct 10, 2007
Particle Detector Development and PerformancePhysics and Astronomy1 references4 citations
TL;DR

This paper measures the angular resolution of the ARGO-YBJ air shower detector using the chessboard method, Monte Carlo (MC) simulations, and a preliminary Moon shadow analysis. It finds that the detector achieves a statistical angular resolution of approximately 0.2° for proton-induced showers at high multiplicity (N_pad ≈ 4000), with systematic errors becoming dominant at large shower sizes, and confirms consistency between data and simulations. The addition of a 0.5 cm lead converter is expected to improve resolution by at least 30% at low multiplicity.

ABSTRACT

The ARGO-YBJ experiment is a full coverage EAS-array installed at the YangBaJing Cosmic Ray Laboratory (4300 m a.s.l., Tibet, P.R. China). We present the results on the angular resolution measured with different methods with the full central carpet. The comparison of experimental results with MC simulations is discussed.

Motivation & Objective

  • To measure the angular resolution of the ARGO-YBJ detector using multiple independent methods to assess pointing accuracy and systematic errors.
  • To evaluate the impact of detector size and shower multiplicity on angular resolution using the chessboard method and MC simulations.
  • To validate the detector's performance through a preliminary Moon shadow analysis, which provides a direct measurement of angular resolution and pointing error.
  • To quantify the contribution of systematic errors—such as core position resolution and shower front profile inaccuracies—to the overall angular resolution.
  • To estimate the expected improvement in angular resolution from adding a 0.5 cm lead converter to the detector surface.

Proposed method

  • The chessboard method splits the detector into two sub-arrays (even and odd pads) and compares the reconstructed shower directions to estimate statistical angular resolution.
  • The Point Spread Function (PSF) is characterized using the ψ72 parameter, defined as the angular opening containing 72% of events, with σθ ≈ ψ72 / 1.58 for Gaussian PSF.
  • Monte Carlo simulations using CORSIKA/QGSJet and GEANT3 models simulate proton and photon-induced showers across energies from 300 GeV to 100 TeV, with core positions reconstructed via maximum likelihood method.
  • Shower core position resolution is evaluated as a function of pad multiplicity, with events selected based on core location within the central carpet and pad multiplicity thresholds.
  • The Moon shadow deficit in cosmic ray flux is analyzed over 558 hours of observation, with event distributions projected along W-E and N-S axes and fitted with Gaussians to extract angular resolution.
  • Systematic errors are estimated by comparing the ratio of (ψ72)_true/rec to (ψ72)_eo, revealing increasing deviation from 0.5 at high multiplicity due to non-statistical errors.

Experimental results

Research questions

  • RQ1What is the angular resolution of the ARGO-YBJ detector as measured by the chessboard method, and how does it vary with pad multiplicity?
  • RQ2To what extent do systematic errors—such as core position uncertainty and shower front profile inaccuracies—limit the angular resolution at high shower sizes?
  • RQ3How well do Monte Carlo simulations reproduce the experimental angular resolution, and what corrections are needed to align them?
  • RQ4What is the contribution of the Moon shadow deficit to the measurement of angular resolution and pointing accuracy?
  • RQ5How much improvement in angular resolution can be expected from adding a 0.5 cm lead converter to the detector surface?

Key findings

  • The angular resolution of ARGO-130, measured via the chessboard method, improves approximately as N_pad^(-0.7), faster than the expected N_pad^(-0.5) due to systematic error contributions.
  • For proton-induced showers with N_pad ≈ 4000 (median energy ~30 TeV), the statistical angular resolution is estimated at ~0.2°, consistent with conservative MC simulations.
  • The ratio (ψ72)_true/rec / (ψ72)_eo increases from ~0.5 at low multiplicity to ~1.0 at high multiplicity, indicating that systematic errors dominate at large shower sizes.
  • The Moon shadow analysis yields a measured angular resolution of σ_W-E = 0.43° and σ_N-S = 0.51° for events with N_pad > 500, consistent with MC predictions and indicating a residual systematic pointing error of ~0.14° in the N-S direction.
  • The addition of a 0.5 cm lead converter is expected to improve angular resolution by at least 30% at low multiplicity (N_pad < few hundreds), enhancing shower profile definition.
  • Photon-induced showers show slightly better angular resolution than proton-induced showers at low multiplicity due to their more sharply defined temporal profiles.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.