Skip to main content
QUICK REVIEW

[Paper Review] Measuring Active-to-Sterile Neutrino Oscillations with Neutral Current Coherent Neutrino-Nucleus Scattering

A. J. Anderson, J. M. Conrad|DSpace@MIT (Massachusetts Institute of Technology)|Jan 18, 2012
Neutrino Physics ResearchPhysics and Astronomy4 citations
TL;DR

This paper proposes a cyclotron-based accelerator experiment using neutral current coherent neutrino-nucleus scattering to directly probe active-to-sterile neutrino oscillations at Δm² ~ 1 eV². By employing low-threshold germanium or liquid argon detectors, the method achieves 3.8–4.8σ sensitivity to the LSND best-fit mass splitting, offering a pure, complementary probe to charged-current searches and enabling definitive constraints on sterile neutrino mixing parameters.

ABSTRACT

Light sterile neutrinos have been introduced as an explanation for a number of oscillation signals at $Δm^2 \sim 1$ eV$^2$. Neutrino oscillations at relatively short baselines provide a probe of these possible new states. This paper describes an accelerator-based experiment using neutral current coherent neutrino-nucleus scattering to strictly search for active-to-sterile neutrino oscillations. This experiment could, thus, definitively establish the existence of sterile neutrinos and provide constraints on their mixing parameters. A cyclotron-based proton beam can be directed to multiple targets, producing a low energy pion and muon decay-at-rest neutrino source with variable distance to a single detector. Two types of detectors are considered: a germanium-based detector inspired by the CDMS design and a liquid argon detector inspired by the proposed CLEAR experiment.

Motivation & Objective

  • To provide a direct, model-independent test for the existence of sterile neutrinos via neutral current coherent scattering.
  • To overcome limitations of charged-current searches, which are sensitive to both active and sterile components, by enabling pure active-to-sterile oscillation sensitivity.
  • To probe the LSND and reactor anomaly parameter spaces at high significance using a single detector with multiple baselines.
  • To leverage existing or near-term detector technologies—germanium and liquid argon—optimized for low-energy nuclear recoils.
  • To establish a new experimental channel for measuring sterile neutrino mixing parameters with minimal model dependence.

Proposed method

  • Utilizes a cyclotron-based proton beam directed at multiple targets to produce low-energy pions and muons, enabling a decay-at-rest (DAR) neutrino source with variable baseline.
  • Employs neutral current coherent neutrino-nucleus scattering, a process with a high cross section in the Standard Model and a recoil energy signature identical to WIMP dark matter detection.
  • Uses two detector types: a germanium-based detector (threshold ~10 keV) inspired by CDMS and a liquid argon detector (threshold ~30 keV) modeled after CLEAR.
  • Measures the distance dependence of the scattering rate to identify oscillation signals, exploiting multiple baselines without moving detectors.
  • Applies a one-sided raster scan in mixing parameters to compute sensitivity limits using Δχ² thresholds.
  • Calculates oscillation probabilities via P(να → νβ≠α) = 4|Uα4|²|Uβ4|² sin²(1.27Δm₄₁²L/E) for appearance and P(να → ν¬α) = 4|Uα4|²(1−|Uα4|²) sin²(1.27Δm₄₁²L/E) for disappearance.

Experimental results

Research questions

  • RQ1Can neutral current coherent neutrino-nucleus scattering provide a pure, direct probe of active-to-sterile neutrino oscillations?
  • RQ2What is the sensitivity of such a search to the LSND anomaly parameter space at Δm² ~ 1.2 eV²?
  • RQ3How do detector thresholds and fiducial masses affect the sensitivity to low-energy nuclear recoils from coherent scattering?
  • RQ4Can this method exclude or confirm the LSND best-fit parameters at high significance?
  • RQ5How does this approach compare to charged-current searches in terms of sensitivity to sterile neutrino mixing parameters?

Key findings

  • A germanium-based detector in the baseline physics run scenario achieves 3.8σ sensitivity to the LSND best-fit mass splitting (Δm² = 1.2 eV²).
  • In a dedicated germanium-based run, the experiment reaches 4.8σ sensitivity to the LSND best-fit Δm², exceeding the 3.8σ level.
  • The 100 kg germanium detector outperforms the 456 kg liquid argon detector due to its lower energy threshold (10 keV vs. 30 keV), enhancing low-recoil event collection.
  • The experiment can exclude nearly all of the 90% CL LSND parameter space for sin²2θee and sin²2θμμ at the 3σ level, assuming Δm² ~ 1.2 eV².
  • The method probes large regions of the reactor anomaly allowed parameter space, particularly for sin²2θee, which is nearly independent of Δm² for Δm² ≥ 1.5 eV².
  • The approach provides a unique, pure active-to-sterile oscillation sensitivity, complementary to charged-current searches, and is sensitive to non-standard neutrino interactions and the weak mixing angle.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.