[Paper Review] Model predictive control for transient frequency regulation of power networks
This paper proposes a distributed model predictive control (MPC) strategy for power networks that ensures both asymptotic stability and transient frequency regulation by solving a finite-horizon optimal control problem with stability and frequency constraints. A reference-trajectory-based convexification technique enables efficient computation, while network partitioning allows each region to compute its control input using only local and neighboring information, achieving safe frequency invariance and finite-time convergence of control inputs.
This paper introduces a control strategy to simultaneously achieve asymptotic stabilization and transient frequency regulation of power networks. The control command is generated by iteratively solving an open-loop control cost minimization problem with stability and transient frequency constraints. To deal with the non-convexity of the stability constraint, we propose a convexification strategy that uses a reference trajectory based on the system's current state. We also detail how to employ network partitions to implement the proposed control strategy in a distributed way, where each region only requires system information from neighboring regions to execute its controller.
Motivation & Objective
- To develop a control strategy that simultaneously guarantees asymptotic stability and transient frequency regulation in power networks under disturbances.
- To address the challenge of non-convex stability constraints in optimal control formulations by introducing a reference-trajectory-based convexification method.
- To enable distributed implementation of the controller using network partitioning, where each region uses only local and neighboring system data.
- To ensure that the safe frequency region is both invariant and attractive under the proposed control law.
- To minimize control effort while maintaining system stability and frequency safety through receding-horizon optimization.
Proposed method
- Formulates a centralized finite-horizon open-loop optimal control problem to minimize cost under stability and transient frequency constraints.
- Introduces a convexification strategy using a reference trajectory derived from the current system state to handle the non-convexity of the stability constraint.
- Defines the closed-loop control input as the first step of the optimal control sequence, enabling a receding-horizon implementation.
- Partitions the power network into regions to enable distributed control, where each region’s controller depends only on its own state and neighboring region dynamics.
- Uses a modified power network model with dynamic frequency and injection deviations to represent transient behavior.
- Applies the controller in both centralized and distributed forms, with performance evaluated on IEEE 9-bus and 30-bus systems.
Experimental results
Research questions
- RQ1Can a model predictive control framework be designed to simultaneously ensure asymptotic stability and transient frequency regulation in power networks?
- RQ2How can the non-convex stability constraint in the optimal control problem be effectively convexified for real-time implementation?
- RQ3To what extent can the control performance be preserved in a distributed architecture that limits information exchange to local and neighboring regions?
- RQ4How does the choice of frequency bounds affect the required control effort and signal shape?
- RQ5What is the trade-off between control effort, computational complexity, and performance in centralized versus distributed MPC implementations?
Key findings
- The proposed centralized MPC controller ensures that the safe frequency region is invariant and attractive, with control inputs vanishing in finite time.
- Tighter transient frequency bounds lead to larger control signals that closely track the negative of power injection deviations, increasing control effort.
- The total control effort is 123.2, 90.1, and 36.5 for frequency bounds of 0.05 Hz, 0.1 Hz, and 0.2 Hz, respectively, showing a significant reduction in effort as bounds loosen.
- When initial generator frequencies are outside the safe region, the controller successfully drives them back and maintains them within bounds after activation at t=10s.
- In the IEEE 9-bus test case, the centralized controller achieves the lowest control cost due to global information access, while the distributed controller incurs higher cost due to lack of inter-region coordination.
- The controller from Zhang and Cortés (2019) incurs the highest control cost, as it is not optimized for control effort, but it is the fastest to compute and requires only 1-hop neighbor information.