[Paper Review] Monitoring stress related velocity variation in concrete with a $2.10^{-5}$ relative resolution using diffuse ultrasound
This study demonstrates a novel diffuse ultrasound technique capable of detecting relative velocity changes in concrete as low as 2×10⁻⁵, corresponding to stress sensitivity below 50 kPa. By applying a stretching-based cross-correlation method to the multiply scattered coda of ultrasonic waves, the approach achieves high-resolution monitoring of stress-induced velocity variations, enabling precise non-linear parameter estimation in heterogeneous materials like concrete.
Ultrasonic waves propagating in solids have stress-dependent velocities. The relation between stress (or strain) and velocity forms the basis of non-linear acoustics. In homogeneous solids, conventional time-of-flight techniques have measured this dependence with spectacular precision. In heterogeneous media like concrete, the direct (ballistic) wave around 500 kHz is strongly attenuated and conventional techniques are less efficient. In this manuscript, the effect of weak stress changes on the late arrivals constituting the acoustic diffuse coda is tracked. A resolution of $2.10^{-5}$ in relative velocity change is attained which corresponds to a sensitivity to stress change of better than 50 kPa. Therefore the technique described here provides an original way to measure the non-linear parameter with stress variations on the order of tens of kPa.
Motivation & Objective
- To develop a high-resolution method for detecting stress-induced velocity variations in heterogeneous concrete using diffuse ultrasonic waves.
- To overcome the limitations of conventional time-of-flight techniques in highly scattering media like concrete.
- To achieve sub-50 kPa stress sensitivity by leveraging the enhanced sensitivity of multiply scattered coda waves to weak perturbations.
- To provide a non-destructive, on-site capable technique for assessing concrete’s non-linear parameter β and structural integrity.
- To validate the technique’s robustness against environmental noise, such as temperature fluctuations.
Proposed method
- The method employs high-frequency (500 kHz) ultrasonic transducers to excite and record diffuse wavefields in a concrete sample under controlled uniaxial loading.
- Ultrasonic signals are cross-correlated with a 10 s chirp signal to compress the impulse response, yielding time-compressed waveforms h_k(t).
- A stretching-based cross-correlation technique is applied to compare waveforms h_k(t) and h_0(t), with the relative velocity change ν estimated as the shift that maximizes cross-correlation.
- The cross-correlation function CC_k(ν) is derived using spectral density ρ(f), bandwidth Δf, and signal-to-noise ratio, with peak detection used to estimate ν_k.
- The technique avoids the assumption of constant time-shift within a window, improving stability and precision over traditional doublet methods.
- Statistical analysis of the cross-correlation peak and noise floor enables estimation of the uncertainty in ν_k, yielding a resolution of 2×10⁻⁵ in dV/V.
Experimental results
Research questions
- RQ1Can diffuse ultrasound coda waves detect relative velocity changes in concrete below 10⁻⁵ under weak stress variations?
- RQ2How does the stretching-based cross-correlation method improve resolution and stability compared to the conventional doublet technique in heterogeneous media?
- RQ3To what extent can environmental factors like temperature fluctuations confound stress-induced velocity measurements in concrete?
- RQ4What is the achievable sensitivity of diffuse ultrasound to stress changes in concrete, and how does it compare to existing non-destructive evaluation techniques?
- RQ5Can this method reliably estimate the non-linear parameter β of concrete with sub-50 kPa stress resolution?
Key findings
- The method achieves a relative velocity resolution of 2×10⁻⁵, corresponding to a stress sensitivity of less than 50 kPa.
- The linear regression of dV/V versus Δσ yields a slope of 10⁻⁶ kPa⁻¹, indicating a non-linear parameter β ≈ -40 for the concrete sample.
- The standard deviation of the regression for dV/V is 2×10⁻⁵, implying a 5% uncertainty in the β estimate.
- Temperature fluctuations of less than 0.8 °C had no measurable effect on velocity variations, confirming that observed changes are primarily stress-induced.
- The stretching technique outperforms the doublet method by not assuming constant time-shifts, resulting in more stable and precise velocity change estimation.
- The technique is robust against strong noise and can compensate for low signal-to-noise ratios by increasing integration time T or bandwidth Δf.
Read this paper
Open the full text in the Nubint reader and ask about any passage as you read.
Read this paper on NubintThis review was generated by AI from the original paper. Please check the paper before citing it.