Skip to main content
QUICK REVIEW

[Paper Review] Multi-axis atom interferometer gyroscope with a single source of atoms

Yun-Jhih Chen, Azure Hansen|arXiv (Cornell University)|Dec 1, 2018
Cold Atom Physics and Bose-Einstein CondensatesPhysics and Astronomy49 references8 citations
TL;DR

This paper demonstrates a multi-axis atom interferometer gyroscope using a single source of cold atoms in a glass vacuum cell, leveraging point-source interferometry (PSI) to simultaneously measure linear acceleration along the Raman beam direction and rotation vector components in the perpendicular plane. With a 1-second averaging time, it achieves sensitivities of 0.033°/s for rotation magnitude and 0.27° for direction, enabling compact, portable inertial sensing with potential for gyrocompassing and precession tracking.

ABSTRACT

Using the technique of point source atom interferometry, we characterize the sensitivity of a multi-axis gyroscope based on free-space Raman interrogation of a single source of cold atoms in a glass vacuum cell. The instrument simultaneously measures the acceleration in the direction of the Raman laser beams and the component of the rotation vector in the plane perpendicular to that direction. We characterize the sensitivities for the magnitude and direction of the rotation vector measurement, which are 0.033 $^{\circ}/\mathrm{s}$ and 0.27 $^{\circ}$ with one second averaging time, respectively. The sensitivity could be improved by increasing the Raman interrogation time, allowing the cold-atom cloud to expand further, correcting the fluctuations in the initial cloud shape, and reducing sources of technical noise. The unique ability of the PSI technique to measure the rotation vector in a plane may permit applications of atom interferometry such as tracking the precession of a rotation vector and gyrocompassing.

Motivation & Objective

  • To develop a compact, low-size-weight-and-power (SWaP) inertial sensor using a single cold-atom source for multi-axis rotation and acceleration sensing.
  • To overcome the limitations of conventional multi-axis gyroscopes that require multiple atom sources or complex pulse sequences.
  • To demonstrate simultaneous measurement of acceleration along the Raman beam direction and rotation vector components in the transverse plane using point-source interferometry (PSI).
  • To evaluate and mitigate systematic errors from finite atomic cloud size and technical noise in rotation vector measurements.
  • To explore applications in gyrocompassing and precession tracking using the 2D sensitivity of PSI to rotation vectors in a plane.

Proposed method

  • Utilizes point-source interferometry (PSI) with a single, isotropically expanding cloud of cold atoms in a glass vacuum cell.
  • Applies a three-pulse Raman beam sequence (beamsplitter-mirror-beamsplitter) to create matter-wave Mach–Zehnder interferometers for each atom.
  • Leverages strong position-velocity correlation in the expanding cloud to preserve interferometer phase shifts, detectable as spatial fringe patterns in atomic population distribution.
  • Measures acceleration from the fringe shift along the Raman beam direction and rotation vector components in the plane perpendicular to that direction from the fringe pattern.
  • Employs imaging of the atomic cloud in the transverse plane to extract phase shifts due to inertial effects.
  • Uses a single Raman beam configuration with a fixed beam direction to sense both acceleration and rotation simultaneously, avoiding the need for multiple sources or beam reconfiguration.

Experimental results

Research questions

  • RQ1Can a single cold-atom source be used to simultaneously measure acceleration and multiple components of rotation in a plane?
  • RQ2How does the finite size of the initial atomic cloud affect the accuracy of rotation vector measurements in a PSI-based gyroscope?
  • RQ3What are the dominant technical noise sources limiting rotation sensitivity in a compact, single-source atom interferometer?
  • RQ4Can PSI-based gyroscopes achieve sufficient sensitivity for practical applications such as gyrocompassing or precession tracking?
  • RQ5How does the sensitivity scale with Raman interrogation time and cloud expansion in a single-source configuration?

Key findings

  • The instrument achieves a rotation vector magnitude sensitivity of 0.033°/s with one second of averaging time, primarily limited by short Raman interrogation time (8 ms).
  • The direction of the rotation vector is measured with a sensitivity of 0.27°, indicating angular resolution limited by technical noise and cloud size effects.
  • Systematic errors from the finite initial cloud size reduce the measured rotation rate to 79–92% of the simulated value, consistent with a Gaussian cloud model and the expected 1−σ₀²/σ_f² correction factor.
  • Rotational phase shifts are insensitive to position-dependent noise and offset fluctuations, as these affect only the interferometer offset, not the rotation measurement to first order.
  • Estimated contributions from rotating mirror and table vibration noise are 2×10⁻³ °/s and 5×10⁻⁵ °/s, respectively, at 1 s averaging time.
  • The two-dimensional sensitivity of PSI enables natural application as a gyrocompass, where Earth’s rotation vector component in the horizontal plane points toward geographic north, and fringe count scales with cosine of latitude.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.