[Paper Review] Multiphoton ghost imaging with classical light
This paper experimentally demonstrates multiphoton ghost imaging using classical pseudothermal light, showing that higher-order intensity correlations (up to fourth order) increase imaging visibility but reduce signal-to-noise ratio (SNR). It establishes that second-order ghost imaging with thermal light provides the optimal balance of SNR and visibility for a fixed number of images, making it most suitable for practical applications despite lower visibility than higher-order methods.
One of the possible types of n-th order ghost imaging is experimentally performed using multi-photon (higher-order) intensity correlations of pseudothermal light. It is shown that although increasing the order of intensity correlations leads to the growth of ghost imaging visibility, it at the same time reduces the signal-to-noise ratio. Therefore, ghost imaging with thermal light is optimal in the second order in the intensity.
Motivation & Objective
- To investigate the trade-off between imaging visibility and signal-to-noise ratio (SNR) in multiphoton ghost imaging using classical pseudothermal light.
- To experimentally verify the theoretical prediction that higher-order intensity correlations improve visibility at the cost of reduced SNR.
- To determine the optimal order of ghost imaging for thermal light in terms of SNR and visibility under fixed sampling conditions.
- To compare the performance of pseudothermal light with nonclassical light (SPDC) in terms of SNR and visibility across different orders of intensity correlation.
Proposed method
- The experiment uses a 2-port Hanbury-Brown and Twiss (HBT) setup to measure n-th order intensity correlation functions, with the signal beam passing through a mask and detected by a bucket detector, and the reference beam split into multiple spatially resolved detectors.
- Intensity correlation functions of order n are calculated using discrete mode approximation, where continuous intensity distributions are replaced by intensities at discrete points, enabling numerical evaluation of higher-order moments.
- The ghost image is reconstructed by scanning the reference detector position and measuring the correlation between the n−1 reference intensities and the total signal intensity collected by the bucket detector.
- Signal-to-noise ratio (SNR) is quantified by computing the mean difference between the signal in the mask region and the background, normalized by the standard deviation of the background.
- Visibility is measured as the ratio of the maximum correlation in the mask region to the average background correlation, with theoretical fits adjusted for experimental factors like laser instability and speckle size inhomogeneity.
- The number of modes M is determined from the full width at half maximum (FWHM) of the speckle pattern, scaled by a constant factor S=1.19 to account for experimental deviations from theoretical assumptions.
Experimental results
Research questions
- RQ1Does increasing the order of intensity correlation in ghost imaging with classical pseudothermal light lead to higher visibility at the expense of SNR?
- RQ2What is the optimal order of ghost imaging for pseudothermal light in terms of maximizing SNR for a fixed number of images?
- RQ3How does the SNR of ghost imaging with pseudothermal light compare to that of nonclassical light (SPDC) across different orders and intensity regimes?
- RQ4Can the visibility improvement from higher-order correlations be compensated by increasing the number of images, and if so, at what cost to measurement time or data volume?
- RQ5How do experimental factors such as laser power instability and speckle inhomogeneity affect the measured correlation functions and the resulting SNR and visibility?
Key findings
- Higher-order ghost imaging (2nd to 4th order) increases visibility, with the 4th-order image showing the highest visibility, as confirmed by experimental data and theoretical fits.
- Despite the increase in visibility, the signal-to-noise ratio (SNR) decreases with increasing order of correlation, with the 4th-order image showing the lowest SNR.
- Second-order ghost imaging yields the highest SNR among all orders tested, making it optimal for practical applications when the number of images is fixed.
- The SNR for pseudothermal light is slightly lower than for SPDC in the single-mode regime (by less than 6%), but the difference increases in the multi-mode regime.
- At high intensities, the SNR values for pseudothermal light and SPDC converge, indicating that both sources perform identically in terms of SNR under high-photon-flux conditions.
- The experimental data show that the observed autocorrelation functions deviate from theoretical predictions by constant factors F₂=0.988, F₃=0.984, and F₄=0.997, which were used to fit the visibility curves and account for experimental noise and instability.
Read this paper
Open the full text in the Nubint reader and ask about any passage as you read.
Read this paper on NubintThis review was generated by AI from the original paper. Please check the paper before citing it.