Skip to main content
QUICK REVIEW

[Paper Review] Neutron Form Factor from Neutrino-Nucleus Coherent Elastic Scattering

Philip S. Amanik, G. C. McLaughlin|ArXiv.org|Jul 27, 2007
Atomic and Subatomic Physics ResearchPhysics and Astronomy1 references7 citations
TL;DR

This paper proposes measuring the neutron form factor of a nucleus via coherent elastic neutrino-nucleus scattering (CE$ν$S) using a low-energy neutrino source and a liquid noble element detector. Using a stopped pion neutrino source at Oak Ridge SNS and a CLEAN-type detector with liquid argon, the study shows that the neutron radius of $^{40}$Ar could be measured to better than 10% precision if systematic uncertainties are kept below 5%.

ABSTRACT

We analyze the prospect of measuring the neutron form factor of a nucleus through the detection of neutrino-nucleus coherent elastic scattering. We predict numbers of events in a liquid noble nuclear recoil detector at a stopped pion neutrino source. We discuss the precision required to distinguish between different theoretical models for the form factor.

Motivation & Objective

  • To explore a novel method for measuring the neutron form factor of a nucleus using coherent elastic neutrino-nucleus scattering (CE$ν$S).
  • To address the persistent uncertainty in neutron radii of medium-to-heavy nuclei, which limits nuclear structure understanding and applications in neutron star physics and atomic parity violation.
  • To demonstrate the feasibility of extracting neutron density distributions using neutrino scattering, offering a complementary approach to parity-violating electron scattering.
  • To evaluate the sensitivity of a detector to distinguish between different theoretical models of the neutron form factor.
  • To assess the potential for high-precision neutron radius measurements using realistic experimental configurations and detector thresholds.

Proposed method

  • The study models the differential cross section for CE$ν$S using the standard model expression involving the weak charge $Q_W$, momentum transfer $Q^2$, and the nuclear form factor $F(Q^2)$.
  • The form factor $F(Q^2)$ is derived as the Fourier transform of the neutron and proton density distributions, with the neutron contribution dominant due to the small value of $(1 - 4\sin^2\theta_W)$.
  • A stopped pion neutrino source at the Oak Ridge Spallation Neutron Source (SNS) is used, providing well-defined, mono-energetic neutrino fluxes ($\nu_e$ and $\bar{\nu}_\mu$) at 20 meters from the target.
  • The CLEAN detector, filled with 1 tonne of liquid argon, is modeled as a cryogenic nuclear recoil detector capable of detecting low-energy nuclear recoils from CE$ν$S events.
  • Event rates are calculated across recoil energy bins (1–140 keV), assuming different neutron radius values ($R_n = R_p \pm 10\%, \pm 20\%$) to assess sensitivity.
  • The analysis accounts for detector threshold effects and evaluates the distinguishability of form factor models based on event rate differences across energy bins.

Experimental results

Research questions

  • RQ1Can coherent elastic neutrino-nucleus scattering be used to extract the neutron form factor of a nucleus?
  • RQ2What level of precision in neutron radius measurement is achievable with a liquid noble element detector at a stopped pion neutrino source?
  • RQ3How do different theoretical models of the neutron form factor manifest in detectable event rate differences across recoil energy bins?
  • RQ4Can the detector distinguish between form factors with varying neutron radii, especially at low recoil energies?
  • RQ5What systematic uncertainties must be controlled to achieve sub-10% precision in neutron radius determination?

Key findings

  • The study predicts that with a 1-tonne liquid argon detector at the Oak Ridge SNS, the neutron radius of $^{40}$Ar can be measured to better than 10% precision if systematic uncertainties are reduced to below 5%.
  • Event rate differences between models with $R_n = R_p \pm 10\%$ and $R_n = R_p \pm 20\%$ are observable in the first 10 keV recoil energy bin, with percentage differences ranging from -1% to +1% for ±10% and -19% to +21% for ±20%.
  • The largest relative differences in event rates occur at low recoil energies (e.g., 130–140 keV), where the form factor's sensitivity to neutron radius variation is most pronounced.
  • The shape of the event spectrum across energy bins, particularly the low-energy tail, provides a signature that can distinguish form factor variations from shifts in standard model parameters like $\sin^2\theta_W$.
  • The method is robust against global shifts in cross section because form factor modifications affect the shape of the spectrum, not just the normalization, especially at low $T$.
  • The approach is general and could be extended to other nuclei such as neon or xenon, and could be implemented at low-energy beta-beam sources as well.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.