Skip to main content
QUICK REVIEW

[Paper Review] New detectors for the kaon and hypernuclear experiments with KaoS at MAMI and with PANDA at GSI

P. Achenbach, C. Ayerbe Gayoso|arXiv (Cornell University)|May 31, 2006
Particle Detector Development and PerformancePhysics and Astronomy1 references7 citations
TL;DR

This paper presents the development and testing of new high-resolution scintillating fibre detectors and high-purity germanium (HPGe) spectrometers for kaon and hypernuclear physics experiments at the MAMI and GSI facilities. It demonstrates that HPGe detectors maintain sub-0.3% energy resolution (FWHM) at 1.2 T magnetic fields, enabling precise gamma-ray spectroscopy essential for PANDA and KaoS experiments.

ABSTRACT

The KaoS spectrometer at the Mainz Microtron MAMI, Germany, is perceived as the ideal candidate for a dedicated spectrometer in kaon and hypernuclei electroproduction. KaoS will be equipped with new read-out electronics, a completely new focal plane detector package consisting of scintillating fibres, and a new trigger system. First prototypes of the fibre detectors and the associated new front-end electronics are shown in this contribution. The Mainz hypernuclei research program will complement the hypernuclear experiments at the planned FAIR facility at GSI, Germany. At the proposed antiproton storage ring the spectroscopy of double Lambda hypernuclei is one of the four main topics which will be addressed by the PANDA Collaboration. The experiments require the operation of high purity germanium (HPGe) detectors in high magnetic fields (B= 1T) in the presence of a large hadronic background. The performance of high resolution Ge detectors in such an environment has been investigated.

Motivation & Objective

  • To develop advanced focal plane detectors for the KaoS spectrometer at MAMI to enable high-efficiency detection of kaons and hypernuclei in electron scattering experiments.
  • To ensure high-resolution gamma-ray spectroscopy using high-purity germanium (HPGe) detectors in strong magnetic fields (up to 1.2 T) typical of the PANDA experiment at GSI.
  • To address the challenge of maintaining energy resolution and signal integrity in high-rate, high-background environments typical of strangeness production experiments.
  • To validate the performance of new front-end electronics and trigger systems for future PANDA and KaoS experiments under realistic magnetic field conditions.

Proposed method

  • Design and testing of a prototype triple detector module using 384 scintillating fibres (Kuraray SCSF-78) grouped into 96-channel front-end boards with multi-anode photomultipliers (MAPMTs) and Cockcroft-Walton voltage multipliers.
  • Implementation of a 60° fibre bundle configuration with double-layered fibre arrays offset by half a fibre spacing to improve detection efficiency and spatial resolution (pitch: 0.42 mm).
  • Use of a SIS3300 100 MHz, 12-bit FADC for digitizing preamplifier signals to extract pulse shapes and energy information via moving window deconvolution (MWD) to correct for exponential signal tails.
  • Measurement of energy resolution (FWHM) of HPGe detectors (Vega and Euroball cluster) in magnetic fields up to 1.2 T using 60Co sources, with background modeling using Gaussian, skewed Gaussian, and step functions.
  • Systematic evaluation of detector performance at various magnetic field orientations and strengths, including full recovery of energy resolution after exposure.

Experimental results

Research questions

  • RQ1Can high-purity germanium detectors maintain sub-0.3% energy resolution (FWHM) in magnetic fields up to 1.2 T, as required for PANDA's double-Λ hypernuclear spectroscopy?
  • RQ2How does the presence of a strong magnetic field (B ≈ 1 T) affect the pulse shape and energy resolution of HPGe detectors used in high-background environments?
  • RQ3What is the optimal configuration of scintillating fibre detectors (in terms of geometry, pitch, and readout electronics) to maximize detection efficiency and spatial resolution for kaon and hypernuclear experiments?
  • RQ4Can moving window deconvolution (MWD) effectively restore the full amplitude of preamplifier signals distorted by exponential decay in high magnetic fields?
  • RQ5How does the orientation of the magnetic field relative to the detector axis influence the energy resolution of segmented HPGe detectors?

Key findings

  • The energy resolution of one Euroball crystal was measured at 0.3% FWHM at 1.2 T, demonstrating feasibility for high-precision gamma-ray spectroscopy in strong magnetic fields.
  • The Vega HPGe detector maintained consistent energy resolution across different magnetic field orientations, with no significant degradation observed at 0.3 T or 1.2 T.
  • The moving window deconvolution (MWD) algorithm successfully restored the initial amplitude of preamplifier signals, enabling accurate energy extraction despite exponential signal tails.
  • The prototype triple detector with 58.4 mm wide fibre bundles and 0.42 mm pitch achieved high detection efficiency and spatial resolution suitable for high-rate kaon detection.
  • No FET failures, vacuum breakdowns, or sparking were observed during two days of continuous operation at 1.2 T, confirming system stability.
  • The energy resolution of the Vega detector improved with increasing FADC sampling window width (M), indicating that longer integration times enhance resolution under magnetic field influence.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.