Skip to main content
QUICK REVIEW

[Paper Review] On-chip error counting for hybrid metallic single-electron turnstiles

Joonas T. Peltonen, V. F. Maisi|arXiv (Cornell University)|Dec 1, 2015
Quantum and electron transport phenomenaPhysics and Astronomy4 citations
TL;DR

This paper demonstrates on-chip, real-time error counting in hybrid metallic single-electron turnstiles using a capacitively coupled SET electrometer to monitor charge transfer between two series-connected SINIS turnstiles. At pumping frequencies up to 100 kHz, it achieves relative error rates as low as 10⁻³, marking the first in-situ detection of pumping errors exceeding detector bandwidth while simultaneously measuring average current, enabling future self-referenced quantum current standards.

ABSTRACT

We perform in-situ detection of individual electrons pumped through a single-electron turnstile based on ultrasmall normal metal - insulator - superconductor tunnel junctions. In our setup, limited by the detector bandwidth, at low repetition rates we observe errorless sequential transfer of up to several hundred electrons through the system. At faster pumping speeds up to 100 kHz, we show relative error rates down to 10^-3, comparable to typical values obtained from measurements of average pumped current in non-optimized individual turnstiles. The work constitutes an initial step towards a self-referenced current standard realized with metallic single-electron turnstiles, complementing approaches based on semiconductor quantum dot pumps. It is the first demonstration of on-chip pumping error detection at operation frequencies exceeding the detector bandwidth, in a configuration where the average pumped current can be simultaneously measured. The scheme in which electrons are counted from the superconducting lead of the turnstile, instead of direct probing of the normal metal island, also enables studies of fundamental higher-order tunneling processes in the hybrid structures, previously not in reach with simpler configurations.

Motivation & Objective

  • To develop a self-referenced current standard based on metallic single-electron turnstiles by enabling real-time error detection at the single-electron level.
  • To overcome the limitation of detector bandwidth by demonstrating error counting at operation frequencies exceeding the detector's temporal resolution.
  • To enable in-situ monitoring of fundamental tunneling processes such as Cooper pair–electron cotunneling (CPE) in hybrid SINIS structures.
  • To provide a scalable platform for simultaneous measurement of average pumped current and individual charge transfer errors in a single on-chip device.
  • To investigate intrinsic error mechanisms in metallic turnstiles, particularly those arising from quasiparticle relaxation and higher-order tunneling events.

Proposed method

  • A dual SINIS turnstile structure is fabricated in series, with a central metallic counting node monitored by a capacitively coupled SET electrometer.
  • The SET detector operates at cryogenic temperatures and is tuned to resolve individual electron tunneling events at low repetition rates.
  • At higher pumping frequencies, the detector bandwidth is exceeded, but rare pumping errors are still counted by integrating the detector signal over time.
  • The system allows simultaneous measurement of the average pumped current and individual charge transfer events via the detector's output.
  • Charge state changes on the superconducting counting node are used to distinguish between one-electron tunneling and two-electron processes like Cooper pair–electron cotunneling (CPE).
  • The setup enables real-time discrimination of tunneling processes based on their distinct voltage and frequency dependencies, particularly through the bias voltage dependence of charge transfer events.

Experimental results

Research questions

  • RQ1Can pumping errors in metallic single-electron turnstiles be detected in real time when the operation frequency exceeds the detector bandwidth?
  • RQ2Can the average pumped current and individual electron transfer events be simultaneously measured in a single on-chip device?
  • RQ3Can higher-order tunneling processes such as Cooper pair–electron cotunneling be distinguished from single-electron tunneling using on-chip charge monitoring at the superconducting lead?
  • RQ4What are the dominant error mechanisms in SINIS turnstiles when quasiparticle relaxation and finite tunneling rates are considered?
  • RQ5Is it feasible to implement a self-referenced current standard based on metallic turnstiles using on-chip error detection?

Key findings

  • At low repetition rates (≤200 Hz), the system detects individual electrons passing through the counting node with near-perfect fidelity, demonstrating errorless sequential transfer of up to several hundred electrons.
  • At pumping frequencies up to 100 kHz, the relative error rate is measured to be as low as 10⁻³, comparable to non-optimized individual turnstiles.
  • The scheme enables error counting at operation frequencies exceeding the detector's bandwidth, a key advancement over previous methods limited by temporal resolution.
  • The on-chip configuration allows simultaneous measurement of average pumped current and individual charge transfer events, enabling direct correlation between current and error statistics.
  • By monitoring the superconducting counting node instead of the normal metal island, the setup enables clear discrimination of two-electron processes like Cooper pair–electron cotunneling (CPE) from single-electron tunneling based on their distinct voltage dependencies.
  • The results demonstrate the feasibility of using on-chip charge counting to probe fundamental tunneling mechanisms in hybrid turnstiles, including two-electron Andreev reflection and quasiparticle relaxation effects.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.