A. D. Bukin|ArXiv.org|Oct 30, 2007
Sensor Technology and Measurement SystemsComputer Science3 references4 citations
TL;DR

This paper investigates the ambiguity in determining parameters of interfering resonances in scattering cross-section data, demonstrating that multiple distinct sets of resonance parameters (masses, widths, coupling constants) can produce identical cross-section shapes. Using analytical derivations and numerical minimization, it shows that for n resonances, up to 2^{n-1} solutions exist, confirmed through simulations for two to four resonances with fixed or energy-dependent widths.

ABSTRACT

In this paper the interfering resonances parameters determination ambiguity is considered. It is shown that there are two solutions for two fixed width resonances. Analytical relation between different solutions is derived. Numeric experiments for fixed width three and four resonances, and for model energy-dependent width two resonances confirm ambiguity of the resonances parameters determination.

Motivation & Objective

  • To investigate the fundamental ambiguity in determining resonance parameters when multiple resonances interfere in scattering cross-section data.
  • To determine whether different sets of resonance parameters (mass, width, coupling constants) can yield identical cross-section shapes.
  • To establish the theoretical and numerical basis for the existence of multiple solutions in resonance parameter extraction.
  • To validate the number of solutions through numerical experiments for two to four resonances with fixed and energy-dependent widths.

Proposed method

  • Derives analytical conditions for identical cross-section shapes using Fourier transforms of Breit-Wigner amplitudes.
  • Uses complex amplitude parametrization with relative phase freedom to reduce variables and derive a system of three nonlinear equations in three unknowns (amplitude magnitudes and relative phase).
  • Introduces a minimization function Φ to search for solutions by comparing predicted and observed amplitudes, using BUKMIN instead of MINUIT due to complex profile.
  • Applies a secondary minimization of Ψ = ∑|A*x∑GjkAk − Rj|² to refine solutions and improve accuracy.
  • Performs numerical experiments with fixed-width two, three, and four resonances, and a model with energy-dependent widths.
  • Systematically explores all 2^{n-1} sign combinations of square roots to locate potential solutions.

Experimental results

Research questions

  • RQ1Can different sets of resonance parameters produce identical cross-section shapes in the presence of interference?
  • RQ2How many distinct solutions exist for the parameter determination of n interfering resonances?
  • RQ3What is the analytical and numerical relationship between different solutions for the same observed cross-section?
  • RQ4How does the ambiguity scale with the number of resonances (n) in the system?
  • RQ5Can numerical minimization reliably locate all possible solutions, and what constraints affect solution convergence?

Key findings

  • For two interfering resonances with fixed widths, two distinct solutions exist, and their parameters are related analytically through a derived transformation.
  • Numerical experiments confirm the existence of multiple solutions: for four resonances, up to eight solutions were localized, consistent with the rule 2^{n-1}.
  • The minimization algorithm successfully located solutions, with the best ones matching initial approximations and yielding Φ minima as low as 7.5×10⁻⁹ and Ψ minima as low as 9.6×10⁻¹⁵.
  • Solutions with non-zero Qj values (amplitude components) were well-recovered upon refinement, while 'bad' initial approximations led to large deviations, indicating sensitivity to starting points.
  • Additional solutions were found by random initialization, confirming that the algorithm does not reliably locate all solutions, but supports the 2^{n-1} rule.
  • The study confirms that for n resonances, the number of physically distinct parameter sets yielding the same cross-section is 2^{n-1}, not unique.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.