[Paper Review] Online Fault Identification of Digital Hydraulic Valves Using a Combined Model-Based and Data-Driven Approach
This paper presents a real-time, online fault identification method for digital hydraulic valves using only existing pressure sensors and a combined model-based/data-driven approach. By modeling flow balance and applying L1-optimization with quantile regression, it identifies jammed valves (open or closed) with high accuracy during normal operation, enabling immediate fault compensation without additional sensors or system interruption.
Robustness and fault-tolerance are desirable properties for hydraulic working machines and field robots. In applications where service personnel do not have easy access to the machine, it is important that the machine can continue its operation despite single machinery faults. Digital hydraulics enables a design which is inherently fault-tolerant by having each hydraulic actuator controlled by a number of parallel on/off valves. The exact state operation of a digital hydraulic system enables model based diagnostics of the hydraulic components and the possibility to compensate for identified faults. This paper presents an approach for identifying faulty valves based on combination of pressure measurements made during the normal operation of the machine and a mathematical model describing the flow balance of the hydraulic system.
Motivation & Objective
- Address the need for fault-tolerant operation in field robots and hydraulic work machines where maintenance access is limited.
- Enable real-time, online diagnostics of digital hydraulic valves without requiring additional sensors beyond standard pressure sensors.
- Leverage the inherent redundancy of digital hydraulic systems (parallel on/off valves) to detect and compensate for single valve faults.
- Develop a method that identifies both open- and closed-position jams in valves using only pressure measurements and a steady-state flow model.
- Ensure robustness against false positives during normal operation while maintaining sensitivity to actual faults.
Proposed method
- Utilizes a steady-state mathematical model of the hydraulic system to predict expected flow and pressure behavior based on valve states.
- Employs L1-optimization (Lasso-type) to identify the most likely fault by minimizing the error between measured and predicted pressures.
- Applies quantile regression to estimate the probability distribution of fault causes, enabling robust identification of the most plausible fault.
- Uses an exponentially weighted moving average (EWMA) filter with λ = 0.10 to smooth fault estimates and reduce false positives during normal operation.
- Only computes fault estimates during time intervals where the target valve state (open/closed) is actively used, improving relevance and accuracy.
- Validates the method using real-world data from an excavator boom and implements it on embedded hardware (NVIDIA Jetson-TK1) via CAN-bus interface.
Experimental results
Research questions
- RQ1Can valve faults in digital hydraulic systems be identified online using only existing pressure sensors and control signals?
- RQ2How accurately can a hybrid model-based and data-driven approach detect both open- and closed-position jams in on/off valves?
- RQ3To what extent does filtering reduce false positives during normal operation when no fault is present?
- RQ4Can the method identify faults in real time without interrupting machine operation?
- RQ5How effective is the approach in distinguishing between actual faults and normal operational variations?
Key findings
- The method successfully identifies jammed valves with high precision: e.g., 0.96 for closed AT5 and 0.92 for closed AT3, indicating strong fault detection capability.
- False positive rates are significantly reduced by filtering—falling from 0.87 (unfiltered) to 0.13 (filtered) in a no-fault scenario, demonstrating robustness.
- The approach detects both open- and closed-position faults, as confirmed by synthetic data for Open PB3, showing the method's generalizability.
- Fault identification is achieved in real time using only three pressure sensors and control signals, with no need for additional instrumentation.
- The method was successfully deployed on embedded hardware (NVIDIA Jetson-TK1), proving feasibility for real-world implementation.
- Demonstration videos confirm the system detects faults (e.g., unplugged valve) during normal operation, enabling immediate fault-aware control.
Read this paper