Skip to main content
QUICK REVIEW

[Paper Review] Optical fiber read-out for liquid argon scintillation light

J. Janicskó Csáthy, T. Bode|arXiv (Cornell University)|Jun 14, 2016
Radiation Detection and Scintillator TechnologiesPhysics and Astronomy12 references9 citations
TL;DR

This paper presents a low-background, anti-Compton veto system for high-purity germanium (HPGe) detectors in liquid argon (LAr), using wavelength-shifting (WLS) fibers coupled to silicon photomultipliers (SiPMs) for scintillation light read-out. The setup achieves suppression factors of 11.8–14.6 for 226Ra and 177 for 232Th sources, demonstrating performance comparable to traditional PMT-based systems, with successful detection of 214Bi–214Po delayed coincidences for enhanced background rejection.

ABSTRACT

In this paper we describe the performance of a light detector for Ar scintillation light made of wavelength-shifting (WLS) fibers connected to Silicon-Photomultipliers (SiPM). The setup was conceived to be used as anti-Compton veto for high purity germanium (HPGe) detectors operated directly in liquid Argon (LAr). Background suppression efficiencies for different radioactive sources were measured in a test cryostat with about 800 kg LAr. This work was part of the R\&D effort for the GERDA experiment.

Motivation & Objective

  • To develop a low-background, compact anti-Compton veto system for HPGe detectors operating directly in liquid argon.
  • To overcome limitations of traditional PMTs in cryogenic, ultra-low-background environments by using SiPMs and WLS fibers.
  • To demonstrate effective suppression of background events from 232Th and 226Ra sources in a real LAr environment.
  • To validate the detection of 214Bi–214Po delayed coincidences for additional background identification in experiments like GERDA.

Proposed method

  • A custom light detector was built using WLS fibers coated with vacuum-deposited TPB to shift scintillation light to visible wavelengths.
  • The WLS fibers were connected to SiPMs located outside the cryostat, with signal transmission via 50 Ω coaxial cables.
  • The system was tested in a 600 L liquid argon cryostat with a 1 m high HPGe detector suspended at mid-height.
  • Radioactive sources (232Th via thorated welding rods and 226Ra via bare metal plates) were placed 1 cm below the HPGe detector to simulate background contamination.
  • Data acquisition used pulser triggers and 25 MHz sampling to record 665 μs traces, enabling analysis of delayed alpha events after gamma triggers.
  • Delayed coincidence analysis was performed by identifying high-multiplicity SiPM signals (>4 channels, >20 p.e.) within 628 μs after HPGe triggers.

Experimental results

Research questions

  • RQ1Can a WLS fiber and SiPM-based system achieve background suppression performance comparable to PMT-based systems in liquid argon?
  • RQ2What is the suppression factor for 232Th and 226Ra sources using this WLS fiber–SiPM configuration in a real LAr environment?
  • RQ3Can 214Bi–214Po delayed coincidences be reliably detected to enable additional background rejection?
  • RQ4Does vacuum-deposited TPB on WLS fibers provide superior performance and durability compared to liquid-based coatings?
  • RQ5What is the effective instrumented volume and background suppression efficiency of a fiber-only system without reflector foils?

Key findings

  • The system achieved a suppression factor of 177 ± 33 for 232Th at 2039 keV, indicating strong background rejection capability.
  • For 226Ra, the suppression factor was measured at 11.8 ± 1.2 at 2039 keV, with a pulser acceptance rate of 95.2%, confirming high detection efficiency.
  • The observed time distribution of alpha events following 214Bi gamma decays showed a half-life of 164.5 ± 4.5 μs, consistent with the 164 μs half-life of 214Po.
  • The detection of 214Bi–214Po delayed coincidences was successfully demonstrated, enabling a potential new background suppression channel.
  • The vacuum-deposited TPB coating on WLS fibers showed superior quality and did not damage the fibers, outperforming liquid-based methods.
  • The suppression factors were found to be compatible with the best results from PMT-based systems, confirming the viability of the WLS–SiPM approach.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.