[Paper Review] Parameter inference in a computational model of hemodynamics in pulmonary hypertension

Amanda L. Colunga, Mitchel J. Colebank|arXiv (Cornell University)|Jan 15, 2021
Pulmonary Hypertension Research and TreatmentsMedicine5 citations
TL;DR

This study develops a patient-specific computational model of pulmonary hemodynamics to infer key physiological parameters in nine pulmonary hypertension (PH) patients using both static right heart catheterization (RHC) data and continuous waveform data. By combining sensitivity analysis, multistart parameter inference, and uncertainty quantification, the model accurately calibrates right atrial reservoir and pump function, with results aligning with known PH pathophysiology and prior non-modeling studies.

ABSTRACT

Pulmonary hypertension (PH), defined by a mean pulmonary arterial pressure (mPAP) $>$ 20 mmHg, is characterized by increased pulmonary vascular resistance and decreased pulmonary arterial compliance. There are few measurable biomarkers of PH progression, but a conclusive diagnosis of the disease requires invasive right heart catheterization (RHC). Patient-specific computational models of the cardiovascular system are a potential noninvasive tool for determining additional indicators of disease severity. Using computational modeling, this study quantifies physiological parameters indicative of disease severity in nine PH patients. The model includes all four heart chambers and the pulmonary and systemic circulations. We consider two sets of calibration data: static (systolic \& diastolic values) RHC data and a combination of static and continuous, time-series waveform data. We determine a subset of identifiable parameters for model calibration using sensitivity analyses and multistart inference, and carry out uncertainty quantification post-inference. Results show that additional waveform data enables accurate calibration of the right atrial reservoir and pump function across the PH cohort. Model outcomes, including stroke work and pulmonary resistance-compliance relations, reflect typical right heart dynamics in PH phenotypes. Lastly, we show that estimated parameters agree with previous, non-modeling studies, supporting this type of analysis in translational PH research.

Motivation & Objective

  • To develop a patient-specific computational model of the cardiovascular system that captures hemodynamics in pulmonary hypertension (PH).
  • To improve noninvasive assessment of PH severity by inferring physiological parameters from clinical data.
  • To evaluate the impact of including continuous time-series hemodynamic waveforms versus static RHC measurements on parameter inference accuracy.
  • To validate inferred parameters against known PH pathophysiological patterns and prior non-modeling studies.
  • To quantify uncertainty in inferred parameters and identify a subset of identifiable parameters through sensitivity analysis.

Proposed method

  • Construct a 1D/0D lumped-parameter model of the systemic and pulmonary circulations, including all four heart chambers.
  • Use static RHC data (systolic and diastolic pressures) and time-series waveform data for model calibration.
  • Apply multistart optimization with global sensitivity analysis to identify a minimal, identifiable subset of parameters.
  • Perform uncertainty quantification using Monte Carlo sampling and Bayesian inference techniques.
  • Calibrate the model using a combination of patient-specific hemodynamic measurements and physiological constraints.
  • Validate model outputs (e.g., stroke work, resistance-compliance relations) against expected PH phenotypes.

Experimental results

Research questions

  • RQ1Can patient-specific computational models accurately infer hemodynamic parameters in PH patients using clinical RHC data?
  • RQ2How does the inclusion of continuous time-series waveform data improve the accuracy of parameter inference compared to static RHC values alone?
  • RQ3Which physiological parameters are identifiable and robust to uncertainty in the context of PH hemodynamics?
  • RQ4Do the inferred parameters and model outputs align with established pathophysiological patterns of pulmonary hypertension?
  • RQ5To what extent do the estimated parameters agree with findings from non-modeling studies in PH?

Key findings

  • The inclusion of continuous time-series waveform data significantly improves the calibration of right atrial reservoir and pump function across the PH cohort.
  • A subset of parameters was identified as identifiable through sensitivity analysis, enabling robust model calibration despite high-dimensional parameter space.
  • Model outputs, including pulmonary resistance-compliance relations and stroke work, reflect typical right heart hemodynamic patterns seen in PH phenotypes.
  • Estimated parameters for pulmonary vascular resistance and arterial compliance are consistent with previously reported values from non-modeling studies.
  • Uncertainty quantification revealed reliable confidence intervals for key parameters, supporting clinical interpretability.
  • The model successfully captures disease-specific hemodynamic phenotypes, demonstrating potential for noninvasive assessment of PH severity.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.