Skip to main content
QUICK REVIEW

[Paper Review] Polymer identification via undetected photons using a low footprint nonlinear interferometer

Atta Ur Rehman Sherwani, Emma Pearce|arXiv (Cornell University)|Mar 23, 2026
Mechanical and Optical ResonatorsPhysics and Astronomy0 citations
TL;DR

Demonstrates a compact nonlinear interferometer that retrieves mid-infrared polymer absorption spectra by detecting only near-infrared photons, enabling field-deployable plastic identification with silicon detectors.

ABSTRACT

Plastic pollution has become a critical global challenge, with microplastics pervading ecosystems and entering human food chains. Effectively monitoring this widespread contamination demands rapid, reliable, and portable material identification techniques that often elude conventional Raman and FTIR spectroscopy. Undetected photon spectroscopy within a nonlinear interferometer (NLI) offers a solution, allowing the retrieval of mid-infrared absorption spectra by detecting only near-infrared signal photons using standard silicon-based technology. Here, we demonstrate a highly compact, micro-integrated, thermally-stabilised NLI with a Michelson-like geometry designed for the rapid spectroscopy of plastics. We benchmarked its room-temperature performance, demonstrating a signal-to-noise ratio of 34 with a measurement rate of 100 Hz and a spectral resolution of 6 cm$^{-1}$. We show that we can accurately and rapidly retrieve the characteristic vibrational absorption spectra of common polymers such as polypropylene, polyethene, and polystyrene, without using mid-infrared technology. These results establish our compact module as a promising field-deployable platform for robust, real-time environmental monitoring systems and other mid-infrared spectroscopy applications.

Motivation & Objective

  • Develop a compact, thermally stabilized nonlinear interferometer (NLI) module for rapid polymer identification in the 3060–2790 cm⁻¹ region.
  • Show that mid-infrared spectra can be retrieved from near-infrared detection via undetected photons.
  • Achieve high SNR and ~6 cm⁻¹ spectral resolution at room temperature suitable for common polymers.
  • Benchmark performance against conventional FTIR/ATR spectra for polymers like PP, PE, and PS.

Proposed method

  • Use spontaneous parametric down-conversion in ppKTP to generate correlated near-IR signal (901–923 nm) and MIR idler (3.26–3.58 μm) photons.
  • Implement a Michelson-like, micro-integrated NLI with double-pass geometry to map idler absorption to signal visibility.
  • Extract transmission spectra from a single interferogram using a Hilbert-transform envelope method and Beer–Lambert conversion.
  • Characterize performance via SNR, Allan-Werle deviation, and a fixed operating point (OPLD ~1.45 mm) to balance resolution (~6 cm⁻¹) and visibility (≈18.5%).
  • Demonstrate identification of PP, PE, and PS by comparing retrieved absorbance spectra to ATR-FTIR references.
Figure 1: Schematic of the Michelson-type NLI. A pump laser (720 nm, shown in blue) is focused into a nonlinear crystal (ppKTP), generating correlated NIR signal (901 - 923 nm, shown in green) and MIR idler photons (3.26 - 3.58 µm, shown in red) via SPDC. The pump and signal are separated from the i
Figure 1: Schematic of the Michelson-type NLI. A pump laser (720 nm, shown in blue) is focused into a nonlinear crystal (ppKTP), generating correlated NIR signal (901 - 923 nm, shown in green) and MIR idler photons (3.26 - 3.58 µm, shown in red) via SPDC. The pump and signal are separated from the i

Experimental results

Research questions

  • RQ1Can a compact NLI retrieve accurate MIR absorption spectra from undetected MIR photons using silicon detectors?
  • RQ2What are the trade-offs between spectral resolution, visibility, and SNR in a micro-integrated NLI for polymer spectroscopy?
  • RQ3How does the system performance (SNR, resolution) compare to conventional field-portable spectroscopy in identifying common plastics?
  • RQ4What optimization paths (crystal length, materials, pump enhancement) can extend dynamic range and speed for field deployment?

Key findings

  • Achieved single-shot SNR of 34 at 10 ms integration time.
  • Demonstrated spectral resolution of about 6 cm⁻¹ in the 3060–2790 cm⁻¹ MIR window.
  • Retrieved mid-IR absorption features for PP, PE, and PS that closely match ATR-FTIR references.
  • Identified intrinsic ppKTP absorption near 3.45 μm as a limiting factor for visibility and dynamic range.
  • Measured maximum visibility around 18.5% (dropping to ~5% at strong absorption), affecting SNR in certain bands.
  • Projected potential SNR improvements with pump enhancement and shorter crystals, enabling faster rates (up to kHz) and hyperspectral imaging.
Figure 2: Measurement and data-extraction procedure for a polypropylene (PP) film using our single-shot scheme (a) A reference interferogram taken without the sample (dark cyan) and an interferogram taken with the sample (red). The shaded region indicates the region omitted for further processing (b
Figure 2: Measurement and data-extraction procedure for a polypropylene (PP) film using our single-shot scheme (a) A reference interferogram taken without the sample (dark cyan) and an interferogram taken with the sample (red). The shaded region indicates the region omitted for further processing (b

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.