[Paper Review] Precise ultra fast single qubit control using optimal control pulses
This paper presents a method for ultra-fast, high-fidelity single-qubit quantum gates in nitrogen-vacancy (NV) centers in diamond using optimal control theory, specifically the Chopped Random Basis (CRAB) algorithm. It achieves fidelity of 95% for π/2 pulses and 99% for π pulses beyond the rotating wave approximation (RWA), enabling precise control in strong driving regimes and demonstrating magnetic resonance in arbitrary reference frames by switching between lab, rotating, and following frames.
Ultra fast and accurate quantum operations are required in many modern scientific areas - for instance quantum information, quantum metrology and magnetometry. However the accuracy is limited if the Rabi frequency is comparable with the transition frequency due to the breakdown of the rotating wave approximation (RWA). Here we report the experimental implementation of a method based on optimal control theory, which does not suffer these restrictions. We realised the most commonly used quantum gates - the Hadamard (π/2 pulse) and NOT (πpulse) gates with fidelities ($F^{\mathrm{exp}}_{π/2}=0.9472\pm0.01$ and $F^{\mathrm{exp}}_π=0.993\pm0.016$), in an excellent agreement with the theoretical predictions ($F^{\mathrm{theory}}_{π/2}=0.9545$ and $F^{\mathrm{theory}}_π=0.9986$). Moreover, we demonstrate magnetic resonance experiments both in the rotating and lab frames and we can deliberately "switch" between these two frames. Since our technique is general, it could find a wide application in magnetic resonance, quantum computing, quantum optics and broadband magnetometry.
Motivation & Objective
- To overcome the limitations of the rotating wave approximation (RWA) in ultra-fast quantum control of single spins.
- To enable precise, high-fidelity single-qubit operations in the strong-driving regime where RWA breaks down.
- To demonstrate experimental realization of optimal control pulses (CRAB) for electron spin gates in NV centers at room temperature.
- To enable magnetic resonance experiments in arbitrary reference frames—lab, rotating, and following—by controlling microwave pulse phases.
- To validate the method experimentally with high-fidelity state preparation and tomography, showing excellent agreement with theoretical predictions.
Proposed method
- The Chopped Random Basis (CRAB) quantum optimization algorithm is used to numerically design microwave control pulses that optimize gate fidelity without relying on the RWA.
- The method employs a derivative-free direct search for multivariable optimization, enabling computational flexibility and parallelization.
- The system is modeled using the NV center Hamiltonian in the lab frame: $ \hat{\mathcal{H}}/(2\pi\hbar) = D\hat{S}_z^2 + \omega_z\hat{S}_z + \sqrt{2}\Gamma_x(t)\hat{S}_x $, with $ D = 2.87 $ GHz and $ \omega_z $ from an external magnetic field.
- Pulse sequences include optical initialization, optimized microwave pulses (CRAB-π/2 and CRAB-π), and state readout via fluorescence, with density matrix tomography to reconstruct the final state.
- Fidelity is calculated using the pure-state overlap: $ F = \sqrt{\langle \Psi | \rho | \Psi \rangle} $, with error propagation accounting for Poisson noise and fitting uncertainty.
- Frame switching is achieved by adjusting the phase of the second microwave pulse: $ \phi = \Delta\omega \tau $, allowing detection in the rotating, following, or lab frame.
Experimental results
Research questions
- RQ1Can optimal control pulses be used to achieve high-fidelity single-qubit gates in the strong-driving regime where the Rabi frequency is comparable to the Larmor frequency?
- RQ2How does the fidelity of ultra-fast single-qubit gates compare between theoretical predictions and experimental realization in NV centers?
- RQ3Can magnetic resonance be performed and observed in multiple reference frames—lab, rotating, and following—using tailored microwave pulses?
- RQ4What is the impact of off-resonant driving on the visibility and detectability of free induction decay (FID) signals in different frames?
- RQ5To what extent can the CRAB algorithm compensate for anharmonic dynamics and maintain high-fidelity control beyond the RWA?
Key findings
- The experimental fidelity for the CRAB-π/2 pulse was measured at $ F^{\text{exp}}_{\pi/2} = 0.95 \pm 0.01 $, closely matching the theoretical prediction of $ F^{\text{theory}}_{\pi/2} = 0.9545 $.
- The CRAB-π pulse achieved an experimental fidelity of $ F^{\text{exp}}_{\pi} = 0.99 \pm 0.016 $, in excellent agreement with the theoretical value of $ F^{\text{theory}}_{\pi} = 0.9986 $.
- The method successfully enabled coherent control in the strong-driving regime, where conventional RWA-based pulses fail due to anharmonic dynamics and counter-rotating terms.
- Magnetic resonance experiments were successfully performed in all three reference frames—lab, rotating, and following—by adjusting the phase of the second microwave pulse.
- The Fourier transform of the FID signal in the rotating frame clearly showed the off-resonance shift of $ \Delta\omega = 3 $ MHz, confirming frame-specific detection.
- The ability to switch between frames by phase control demonstrates full control over the reference frame of the measurement, enabling flexible quantum control in broadband magnetometry and quantum sensing.
Read this paper
Open the full text in the Nubint reader and ask about any passage as you read.
Read this paper on NubintThis review was generated by AI from the original paper. Please check the paper before citing it.