Skip to main content
QUICK REVIEW

[Paper Review] PRISM: A Multi-Modal Generative Foundation Model for Slide-Level Histopathology

George Shaikovski, Adam Casson|arXiv (Cornell University)|May 16, 2024
AI in cancer detectionComputer Science12 citations
TL;DR

PRISM is a slide-level, multi-modal foundation model for H&E histopathology pre-trained with clinical reports; it enables zero-shot cancer detection/sub-typing, label-efficient biomarker prediction, and interpretable report generation from whole slide images.

ABSTRACT

Foundation models in computational pathology promise to unlock the development of new clinical decision support systems and models for precision medicine. However, there is a mismatch between most clinical analysis, which is defined at the level of one or more whole slide images, and foundation models to date, which process the thousands of image tiles contained in a whole slide image separately. The requirement to train a network to aggregate information across a large number of tiles in multiple whole slide images limits these models' impact. In this work, we present a slide-level foundation model for H&E-stained histopathology, PRISM, that builds on Virchow tile embeddings and leverages clinical report text for pre-training. Using the tile embeddings, PRISM produces slide-level embeddings with the ability to generate clinical reports, resulting in several modes of use. Using text prompts, PRISM achieves zero-shot cancer detection and sub-typing performance approaching and surpassing that of a supervised aggregator model. Using the slide embeddings with linear classifiers, PRISM surpasses supervised aggregator models. Furthermore, we demonstrate that fine-tuning of the PRISM slide encoder yields label-efficient training for biomarker prediction, a task that typically suffers from low availability of training data; an aggregator initialized with PRISM and trained on as little as 10% of the training data can outperform a supervised baseline that uses all of the data.

Motivation & Objective

  • Motivate slide-level foundation modeling in computational pathology to overcome aggregation challenges across many tiles in WSIs.
  • Develop PRISM to fuse Virchow tile embeddings with clinical text for slide-level representations and report generation.
  • Demonstrate zero-shot, linear probing, and fine-tuning capabilities for cancer detection, cancer sub-typing, and biomarker prediction.
  • Show that text-guided pre-training improves performance and data efficiency over fully supervised aggregators.
  • Explore interpretability of generated pathology reports and tile-level attention.

Proposed method

  • Pre-train a slide-level encoder (Perceiver) to aggregate Virchow tile embeddings into a single slide embedding.
  • Use a BioGPT language model as the decoder and align slide embeddings with rewritten clinical reports via contrastive loss.
  • Train with a CoCa-like objective combining contrastive alignment and autoregressive report generation (teacher-forcing).
  • Pre-process clinical reports by extracting diagnosis and rewriting with GPT-4 to create concise summaries.
  • Fine-tune the slide encoder on downstream tasks with linear classifiers or end-to-end fine-tuning.
  • Evaluate zero-shot, linear probing, and fine-tuning on cancer detection, cancer sub-typing, and biomarker prediction tasks.

Experimental results

Research questions

  • RQ1Can a slide-level foundation model trained with clinical reports achieve zero-shot cancer detection and sub-typing without task-specific supervision?
  • RQ2Does aggregating tile embeddings into a slide-level representation improve performance over tile-level or scratch-trained aggregators for downstream tasks?
  • RQ3How does pre-training with clinical report supervision affect data efficiency for biomarker (MSK-IMPACT) prediction?
  • RQ4Are generated clinical reports interpretable and aligned with histopathological features in slides?

Key findings

  • PRISM achieves zero-shot cancer detection and sub-typing performance approaching or exceeding supervised aggregators on several tasks.
  • Linear probing with pre-trained slide embeddings surpasses the fully supervised baseline on cancer sub-typing and detection tasks.
  • Fine-tuning the pre-trained slide encoder yields strong performance in low-data biomarker prediction, outperforming baselines when training data is limited (e.g., with as little as 10–50% of data).
  • Pre-training with clinical reports improves data efficiency and reduces performance variance across runs for several biomarkers.
  • Generated reports show qualitative correspondence between attentive tiles and histological features mentioned in the text by pathologists.
  • PRISM supports interpretable slide-level embeddings and text-based report generation without task-specific supervision.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.