Skip to main content
QUICK REVIEW

[Paper Review] Proton Tracking Algorithm in a Pixel-Based Range Telescope for Proton Computed Tomography

Helge Egil Seime Pettersen, Ilker Meriç|arXiv (Cornell University)|Jun 17, 2020
Radiation Therapy and DosimetryMedicine6 citations
TL;DR

This paper presents a track-following algorithm for reconstructing proton trajectories in a pixel-based range telescope (Digital Tracking Calorimeter) designed for proton computed tomography. The algorithm minimizes angular deviation while growing tracks from front-layer pixels, successfully reconstructing up to several hundred concurrent proton tracks with high efficiency, enabling beam intensities of 5–25 million protons per second.

ABSTRACT

Proton Computed Tomography (CT) is a prototype imaging modality for the reconstruction of the Relative Stopping Power of a patient, for more accurate calculations of the dose distributions in proton therapy dose planning. The measurements needed for the reconstruction of a proton CT image are: i) each initial proton vector incident on the imaged object, ii) each proton vector incident on the front face of the detector and iii) the stopping depth of each proton in the detector. In this study, a track reconstruction algorithm is adapted for a planned pixel-based particle-tracking range telescope for proton CT, called the Digital Tracking Calorimeter (DTC). The algorithm is based on the track-following scheme, in which a growing track searches for deeper-laying activated pixels, while minimizing the accumulated angular change. The algorithm is applied to Monte Carlo-simulated output of the DTC, showing that the DTC is able to reconstruct the tracks and find the depths of up to several hundred simultaneous proton tracks.

Motivation & Objective

  • To develop a robust proton tracking algorithm for a pixel-based range telescope to enable clinical proton CT by accurately reconstructing proton trajectories.
  • To address the challenge of reconstructing multiple concurrent proton tracks in the presence of multiple Coulomb scattering and inelastic nuclear interactions.
  • To maximize beam intensity in proton CT systems by minimizing false track reconstructions and improving tracking efficiency.
  • To adapt proven High Energy Physics tracking techniques to the specific needs of proton CT, particularly for range and angle reconstruction.
  • To evaluate the algorithm’s performance under realistic beam conditions, including varying proton densities and scattering effects.

Proposed method

  • The algorithm uses a track-following scheme that grows tracks from the front face of the detector by searching for deeper-laid activated pixels with minimal cumulative angular deviation.
  • It employs a greedy search strategy that prioritizes pixel clusters with the smallest angular deviation from the current track direction to reduce misreconstruction.
  • The reconstruction is performed layer-by-layer, starting from the first active pixel layer, and continues until no further valid pixel connections are found.
  • The algorithm is implemented in C++/ROOT6 and optimized for single-CPU execution, with potential for parallelization and further optimization.
  • Fake track rejection is achieved through post-processing filters, including a 3σ cut on Water Equivalent Path Length (WEPL) values to reduce false positives.
  • Monte Carlo simulations of the DTC prototype are used to evaluate performance under realistic beam conditions, including scattering and nuclear interactions.

Experimental results

Research questions

  • RQ1Can a track-following algorithm effectively reconstruct multiple concurrent proton tracks in a pixel-based range telescope under realistic scattering and interaction conditions?
  • RQ2What is the maximum proton beam intensity the algorithm can handle before reconstruction quality degrades due to track confusion or false positives?
  • RQ3How do inelastic nuclear scattering and multiple Coulomb scattering affect track reconstruction accuracy and fake rate?
  • RQ4Can the algorithm maintain high efficiency and low fake rates at beam intensities relevant for clinical proton CT acquisition times?
  • RQ5How does the choice of reconstruction seed (front vs. distal layer) influence track reconstruction performance and computational load?

Key findings

  • The algorithm successfully reconstructs up to several hundred concurrent proton tracks in simulated data from the DTC prototype.
  • At low proton densities (np < 5), the main source of fake tracks is inelastic nuclear scattering, contributing approximately 1%–2% of false reconstructions.
  • At high densities (np > 50), multiple Coulomb scattering becomes the dominant source of confusion, significantly degrading reconstruction quality.
  • The algorithm achieves a maximum beam intensity of 5–25 million protons per second, depending on beam spot size and acceptable fake rate.
  • The current reconstruction time is 26 ms per proton, which is insufficient for clinical use and requires further optimization and parallelization.
  • A 3σ filter on WEPL values is effective in reducing fake tracks, suggesting a viable path to improve reconstruction fidelity under high-rate conditions.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.