Skip to main content
QUICK REVIEW

[Paper Review] Quantification of heparin in complex matrices (including urine) using a mix-and-read fluorescence assay

Ulrich Warttinger, Roland Krämer|arXiv (Cornell University)|Nov 8, 2016
Proteoglycans and glycosaminoglycans researchBiochemistry, Genetics and Molecular Biology18 references5 citations
TL;DR

This study presents a simple, mix-and-read fluorescence assay using Heparin Red to quantify heparin in complex matrices such as urine with high specificity and sensitivity. The method enables direct, accurate detection of heparin at low microgram per mL levels without interference from common impurities or matrix components, making it suitable for quality control and pharmacokinetic studies.

ABSTRACT

Heparin is an important anticoagulant drug, about one billion doses are produced annually. It is a polydisperse sulfated polysaccharide, and the inherent heterogeneity makes the analysis of heparin difficult. The global crisis resulting from adulterated heparin in 2008 has drawn renewed attention to the challenges that are associated with the quality control and characterization of this complex biological medicine from natural sources. The present study addresses the need for simple and user-friendly analytical methods for the fast and accurate quantification of heparin in complex matrices. Direct quantification of heparin in the low microgram per mL range was accomplished using a specific commercially available assay based on the fluorescent molecular probe Heparin Red, simply by mixing the heparin containing sample and a reagent solution in a 96-well microplate followed by fluorescence readout. A screening of typical impurities in raw heparin (selected other glycosaminoglycans, residual nucleic acids and proteins), related to the extraction from animal tissues, as well as of components of the urine matrix (inorganic salts, amino acids, trace proteins) revealed that these compounds even in large excess have no or very little effect on the accuracy of heparin determination. Heparin spike detection in urine, a biological multicomponent matrix, also showed good accuracy. We envision applications of this mix-and-read assay in the process and quality control in heparin manufacturing, but also in pharmacokinetic studies as a convenient tool for measuring of the urinary excretion of heparins.

Motivation & Objective

  • To develop a rapid, user-friendly method for quantifying heparin in complex biological matrices such as urine.
  • To address challenges in heparin analysis due to its polydisperse, heterogeneous nature and historical contamination issues.
  • To evaluate the specificity and robustness of the assay against common impurities found in raw heparin and urine components.
  • To enable practical application in pharmaceutical manufacturing quality control and urinary excretion monitoring in pharmacokinetic studies.

Proposed method

  • A mix-and-read fluorescence assay was employed using the commercially available Heparin Red probe, which binds specifically to heparin and exhibits enhanced fluorescence upon binding.
  • Samples were mixed with the Heparin Red reagent in a 96-well microplate format, allowing high-throughput analysis.
  • Fluorescence intensity was measured directly after mixing, with quantification based on a standard curve generated from known heparin concentrations.
  • The assay was tested for interference using a range of potential matrix components, including glycosaminoglycans, nucleic acids, proteins, inorganic salts, amino acids, and trace proteins.
  • Urine samples were spiked with heparin to assess recovery and accuracy under biologically relevant conditions.
  • The method was validated for linearity, limit of detection, and precision in complex matrices.

Experimental results

Research questions

  • RQ1Can a simple, mix-and-read fluorescence assay achieve accurate heparin quantification in complex matrices like urine?
  • RQ2To what extent do common impurities in raw heparin or urine components interfere with the fluorescence-based detection of heparin?
  • RQ3Is the assay sensitive and specific enough to detect heparin at low microgram per mL concentrations in biological samples?
  • RQ4Can this method be reliably applied in pharmaceutical quality control and pharmacokinetic studies involving urinary excretion of heparin?

Key findings

  • The assay enabled direct quantification of heparin in the low microgram per milliliter range with high sensitivity and reproducibility.
  • No significant interference was observed from selected glycosaminoglycans, nucleic acids, proteins, inorganic salts, amino acids, or trace proteins, even at large excesses.
  • Heparin spike recovery in urine matrices was accurate, demonstrating the method's robustness in biologically complex environments.
  • The mix-and-read format allows for high-throughput, low-cost, and user-friendly analysis without sample pretreatment.
  • The method shows strong potential for application in industrial quality control and pharmacokinetic studies of heparin excretion.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.