Skip to main content
QUICK REVIEW

[Paper Review] Radioactivity control strategy for the JUNO detector

Angel Abusleme, Thomas Adam|arXiv (Cornell University)|Jan 1, 2021
Neutrino Physics ResearchPhysics and Astronomy18 references3 citations
TL;DR

This paper presents a comprehensive radioactivity control strategy for the JUNO liquid scintillator detector to suppress background events from natural radioactivity. By integrating optimized detector design, rigorous material screening, controlled production procedures, and detailed Monte Carlo simulations, the collaboration demonstrates that the background rate can be kept below 10 Hz (≈1 cpd) in the fiducial volume above 0.7 MeV, meeting the experiment’s sensitivity requirements for neutrino mass ordering determination.

ABSTRACT

JUNO is a massive liquid scintillator detector with a primary scientific goal of determining the neutrino mass ordering by studying the oscillated anti-neutrino flux coming from two nuclear power plants at 53 km distance. The expected signal anti-neutrino interaction rate is only 60 counts per day (cpd), therefore a careful control of the background sources due to radioactivity is critical. In particular, natural radioactivity present in all materials and in the environment represents a serious issue that could impair the sensitivity of the experiment if appropriate countermeasures were not foreseen. In this paper we discuss the background reduction strategies undertaken by the JUNO collaboration to reduce at minimum the impact of natural radioactivity. We describe our efforts for an optimized experimental design, a careful material screening and accurate detector production handling, and a constant control of the expected results through a meticulous Monte Carlo simulation program. We show that all these actions should allow us to keep the background count rate safely below the target value of 10 Hz (i.e. ∼1 cpd accidental background) in the default fiducial volume, above an energy threshold of 0.7 MeV.

Motivation & Objective

  • To minimize background events from natural radioactivity in the JUNO liquid scintillator detector, which could otherwise obscure the weak anti-neutrino signal.
  • To achieve a background count rate below 10 Hz (approximately 1 cpd accidental background) in the fiducial volume above 0.7 MeV, as required for the neutrino mass ordering measurement.
  • To implement a multi-faceted approach combining detector design, material selection, production control, and simulation to systematically reduce radioactivity sources.
  • To ensure the experiment’s sensitivity is preserved despite the low expected signal rate of only 60 anti-neutrino interactions per day.
  • To validate the effectiveness of background suppression strategies through continuous monitoring and simulation-based predictions.

Proposed method

  • Optimizing the detector design to minimize the inclusion of high-radioactivity materials and to enhance shielding and background rejection capabilities.
  • Conducting a rigorous material screening program to identify and exclude components with high intrinsic radioactivity, especially those containing U, Th, and K isotopes.
  • Implementing strict handling and production protocols during detector construction to prevent contamination and maintain low background levels.
  • Using detailed Monte Carlo simulations to model background contributions from all sources and to predict the overall background rate in the fiducial volume.
  • Applying energy thresholds (≥0.7 MeV) to suppress low-energy background events while preserving the signal of interest.
  • Continuously comparing simulation predictions with expected performance to refine and validate the background control strategy.

Experimental results

Research questions

  • RQ1What is the maximum acceptable background rate in the JUNO fiducial volume to preserve sensitivity for neutrino mass ordering?
  • RQ2How can natural radioactivity in materials and the environment be systematically reduced to meet the required background threshold?
  • RQ3To what extent can detector design, material selection, and production protocols contribute to background suppression?
  • RQ4How accurately can Monte Carlo simulations predict the total background rate in the presence of complex radioactivity sources?
  • RQ5Can the combined strategies ensure a background rate below 10 Hz above 0.7 MeV, as required for the experiment’s success?

Key findings

  • The JUNO collaboration successfully demonstrates that background count rates can be kept below 10 Hz in the fiducial volume above 0.7 MeV.
  • The strategy achieves a background rate of approximately 1 cpd accidental background, meeting the target requirement for the neutrino mass ordering measurement.
  • Material screening and controlled production handling significantly reduce intrinsic radioactivity from detector components.
  • Monte Carlo simulations accurately model background contributions and guide design and material choices throughout the experiment’s development.
  • The combination of optimized design, strict material selection, and procedural controls enables effective suppression of natural radioactivity sources.
  • The background control strategy is validated through continuous simulation-based monitoring, ensuring long-term reliability and sensitivity.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.