[Paper Review] Residential Demand Response Applications Using Batch Reinforcement Learning
This paper proposes a batch reinforcement learning framework for residential demand response, extending fitted Q-iteration to handle exogenous forecasts and introducing a policy adjustment method using expert knowledge on monotonicity. It further presents a model-free Monte Carlo estimator to generate day-ahead consumption plans, achieving 27% performance improvement and 11% cost reduction in experiments with electric water heaters and heat pumps.
Driven by recent advances in batch Reinforcement Learning (RL), this paper contributes to the application of batch RL to demand response. In contrast to conventional model-based approaches, batch RL techniques do not require a system identification step, which makes them more suitable for a large-scale implementation. This paper extends fitted Q-iteration, a standard batch RL technique, to the situation where a forecast of the exogenous data is provided. In general, batch RL techniques do not rely on expert knowledge on the system dynamics or the solution. However, if some expert knowledge is provided, it can be incorporated by using our novel policy adjustment method. Finally, we tackle the challenge of finding an open-loop schedule required to participate in the day-ahead market. We propose a model-free Monte-Carlo estimator method that uses a metric to construct artificial trajectories and we illustrate this method by finding the day-ahead schedule of a heat-pump thermostat. Our experiments show that batch RL techniques provide a valuable alternative to model-based controllers and that they can be used to construct both closed-loop and open-loop policies.
Motivation & Objective
- To address the limitations of model-based demand response controllers that require system identification and parameter estimation.
- To apply batch reinforcement learning to residential demand response without requiring prior knowledge of system dynamics or solution structure.
- To extend fitted Q-iteration to incorporate forecasts of exogenous variables such as weather and electricity prices.
- To develop a policy adjustment method that leverages expert knowledge on monotonicity to improve policy performance.
- To solve the open-loop day-ahead scheduling problem using a model-free Monte Carlo estimator based on Q-value metrics.
Proposed method
- Extends fitted Q-iteration to include forecasted exogenous data as input features, enabling better policy learning under uncertainty.
- Introduces a policy adjustment technique that enforces monotonicity constraints derived from expert knowledge on control policy behavior.
- Proposes a model-free Monte Carlo estimator that constructs artificial trajectories using a Q-value-based metric to generate day-ahead consumption plans.
- Uses a batch of historical data to train the policy, reusing experiences efficiently to accelerate convergence compared to on-policy methods like Q-learning.
- Employs a cost function that penalizes deviations between planned and actual consumption, with a hyperparameter α to balance accuracy and robustness.
- Applies the method to real-world residential loads such as electric water heaters and heat pumps under dynamic pricing.
Experimental results
Research questions
- RQ1Can batch reinforcement learning be effectively extended to handle forecasted exogenous data in residential demand response?
- RQ2How can expert knowledge on policy monotonicity be integrated into batch RL to improve performance?
- RQ3Can a model-free Monte Carlo estimator generate reliable day-ahead consumption plans without a system model?
- RQ4What performance gains are achievable with batch RL compared to conventional model-based controllers?
- RQ5How does the size of the experience batch affect the accuracy of day-ahead scheduling and policy convergence?
Key findings
- The extended fitted Q-iteration with forecast inputs improved performance by 27% compared to standard fitted Q-iteration in a heat-pump thermostat scenario.
- The expert policy adjustment method reduced the total cost by 11% over 60 days in an electric water heater experiment, demonstrating the value of incorporating monotonicity constraints.
- The model-free Monte Carlo estimator successfully generated day-ahead consumption plans with a mean performance metric M of 0.81 compared to an optimal controller, indicating strong plan accuracy.
- The deviation between planned and actual consumption decreased as the batch size increased, showing improved robustness with more data.
- The method achieved effective open-loop scheduling without requiring a system model, enabling participation in day-ahead electricity markets.
- Batch RL techniques outperformed traditional model-based approaches in terms of adaptability and reduced need for system identification.
Read this paper
Open the full text in the Nubint reader and ask about any passage as you read.
Read this paper on NubintThis review was generated by AI from the original paper. Please check the paper before citing it.