TL;DR

This paper proposes a worst-case scenario methodology to assess the robustness of electricity systems with near-100% renewable energy, using hourly data from Spain’s last decade to determine optimal photovoltaic and storage capacity. It finds that with 40% dispatchable hydro and cost reductions in PV and storage, the system can achieve a reliable, low-cost supply with a levelized cost of electricity (LCOE) below current market prices.

ABSTRACT

Several research studies have shown that future sustainable electricity systems, mostly based on renewable generation and storage, are feasible with current technologies and costs. However, recent episodes of extreme weather conditions, probably associated with climate change, cast shades of doubt on whether the resulting generation portfolios are sufficiently robust to assure, at all times, a suitable balance between generation and demand, when adverse conditions are faced. To address this issue, this work elaborates a methodology intended to determine a sustainable electricity system that can endure extreme weather conditions, which are likely to occur. First, using hourly production and demand data from the last decade, along with estimates of new uses of electricity, a worst-case scenario is constructed, including the storage capacity and additional photovoltaic power which are needed to serve the demand on an hourly basis. Next, several key parameters which may have a significant influence on the LCOE are considered, and a sensitivity analysis is carried out to determine their real impact, significance and potential trends. The proposed methodology is then applied to the Spanish system. The results show that, under the hypotheses and conditions considered in this paper, it is possible to design a decarbonized electricity system that, taking advantage of existing sustainable assets, satisfies the long-term needs by providing a reliable supply at an average cost significantly lower than current market prices.

Motivation & Objective

  • To develop a methodology for assessing the robustness of renewable electricity systems under extreme weather conditions.
  • To determine the required photovoltaic and storage capacity for reliable 24/7 supply in a worst-case scenario.
  • To analyze the sensitivity of the levelized cost of electricity (LCOE) to key system parameters such as wind and hydro utilization factors, battery costs, and PV deployment.

Proposed method

  • Uses hourly generation and demand data from the past decade to construct a worst-case scenario for the Spanish power system.
  • Applies an iterative optimization algorithm to size photovoltaic and battery storage capacity to meet hourly demand under extreme conditions.
  • Separates dispatchable hydro from regular hydropower based on selected dispatchability levels (40%, 55%, 70%, 85%).
  • Employs a dynamic energy balance equation to ensure hourly supply-demand equilibrium, accounting for storage charging/discharging and state of charge (SoC) constraints.
  • Performs an iterative reduction of storage capacity until the minimum feasible size is reached that still satisfies all hourly balances.
  • Estimates LCOE for each optimized configuration of PV and storage, updating costs as PV capacity increases and storage decreases.

Experimental results

Research questions

  • RQ1What is the minimum required photovoltaic and storage capacity needed to ensure 100% renewable supply under worst-case weather and demand conditions in Spain?
  • RQ2How sensitive is the levelized cost of electricity (LCOE) to variations in key parameters such as wind utilization factor, hydro dispatchability, and battery costs?
  • RQ3To what extent do expected cost reductions in PV and storage technologies lower the LCOE in a fully renewable system?

Key findings

  • The worst-case LCOE for the Spanish system is lower than current wholesale market prices under the study's assumptions.
  • A 40% dispatchable hydro share reduces LCOE by 0.4% per 10% increase in dispatchability, with diminishing returns beyond that.
  • A 10% reduction in PV or battery costs leads to a 2% reduction in LCOE, implying potential annual LCOE reductions of up to 8% if cost trends continue.
  • The required storage capacity is modest when at least 40% of hydro is dispatchable, indicating hydro's critical role in system stability.
  • The methodology successfully identifies an optimal RES and storage portfolio that ensures reliable, low-cost, decarbonized electricity supply.
  • The proposed approach is generalizable and can be applied to other systems and latitudes.