This paper proposes a self-supervised CT denoising method that generates realistic pseudo-CT image pairs using an ensemble of pre-trained noise models to simulate low-dose CT (LDCT) noise. By iteratively refining a denoising model using these pseudo-pairs, the approach significantly improves denoising performance across multiple baseline methods without requiring labeled LDCT/NDCT pairs, achieving state-of-the-art results on the 2016 AAPM Grand Challenge dataset.
Recently, Self-supervised learning methods able to perform image denoising without ground truth labels have been proposed. These methods create low-quality images by adding random or Gaussian noise to images and then train a model for denoising. Ideally, it would be beneficial if one can generate high-quality CT images with only a few training samples via self-supervision. However, the performance of CT denoising is generally limited due to the complexity of CT noise. To address this problem, we propose a novel self-supervised learning-based CT denoising method. In particular, we train pre-train CT denoising and noise models that can predict CT noise from Low-dose CT (LDCT) using available LDCT and Normal-dose CT (NDCT) pairs. For a given test LDCT, we generate Pseudo-LDCT and NDCT pairs using the pre-trained denoising and noise models and then update the parameters of the denoising model using these pairs to remove noise in the test LDCT. To make realistic Pseudo LDCT, we train multiple noise models from individual images and generate the noise using the ensemble of noise models. We evaluate our method on the 2016 AAPM Low-Dose CT Grand Challenge dataset. The proposed ensemble noise model can generate realistic CT noise, and thus our method significantly improves the denoising performance existing denoising models trained by supervised- and self-supervised learning.
Motivation & Objective
- To address the limited availability of paired LDCT and NDCT images for training robust CT denoising models.
- To overcome the limitations of random or Gaussian noise in self-supervised learning for CT, which does not reflect real CT noise characteristics.
- To develop a model-agnostic framework that enhances existing supervised and self-supervised denoising methods using realistic pseudo-CT image pairs.
- To generate high-fidelity pseudo-LDCT images by leveraging an ensemble of noise models trained on individual LDCT/NDCT pairs.
Proposed method
- Pre-train a denoising model to predict NDCT from LDCT using available LDCT/NDCT pairs.
- Pre-train multiple individual LDCT noise models to estimate the difference map (NDCT - LDCT), representing CT-specific noise.
- Generate pseudo-CT image pairs by applying the ensemble of noise models to a test LDCT image to produce realistic pseudo-LDCT and pseudo-NDCT images.
- Fine-tune the denoising model using the generated pseudo-CT pairs as a self-supervised learning objective.
- Use an ensemble of noise models to improve the realism and diversity of generated noise, avoiding overfitting to a single noise pattern.
- Apply the method to existing models (N2C, N2N, N2V) to demonstrate model-agnostic performance gains.
Experimental results
Research questions
- RQ1Can self-supervised learning using pseudo-CT image pairs improve CT denoising performance without requiring labeled LDCT/NDCT pairs?
- RQ2Can an ensemble of noise models generate more realistic CT noise than random or Gaussian noise in self-supervised denoising?
- RQ3Does the proposed method improve the performance of existing supervised and self-supervised denoising models in a model-agnostic manner?
- RQ4How does the quality of generated pseudo-LDCT images affect the final denoising performance?
Key findings
- The proposed method significantly improves denoising performance across all tested baseline models (N2C, N2N, N2V), demonstrating its model-agnostic nature.
- The ensemble noise model outperforms single noise models and random noise (Gaussian, Hist), generating more realistic noise that better matches actual CT noise characteristics.
- Pseudo-CT image pairs generated using the ensemble noise model preserve key CT image features and reduce artifacts compared to those generated with random noise.
- Quantitative results show that the method achieves higher PSNR and SSIM scores than baseline methods, with the largest gains observed in self-supervised approaches like N2N and N2V.
- The method achieves state-of-the-art performance on the 2016 AAPM Low-Dose CT Grand Challenge dataset, even without access to large-scale labeled data.
- The ablation study confirms that high-quality pseudo-LDCT generation is critical for effective self-supervised fine-tuning, as poor-quality pseudo-images degrade performance.
Read this paper