This paper proposes a sensor-movement-robust, calibration-free method for 3-DoF lower limb joint angle estimation using inertial measurement units (IMUs). It employs a feedback-based iterative algorithm to estimate joint axes and a pointwise reference frame calibration using fused gravity and magnetic field vectors, achieving sub-2° RMS error in 2-minute level walking and robustness against sensor movement and misplacement.
Inertial measurement unit (IMU)-based 3-DoF angle estimation methods for lower limb joints have been studied for decades, however the calibration motions and/or careful sensor placement are still necessary due to challenges of real-time application. This study proposes a novel sensormovement-robust 3-DoF method for lower-limb joint angle estimation without calibration. A realtime optimization process, which is based on a feedback iteration progress to identify three joint axes of a 3-DoF joint, has been presented with a reference frame calibration algorithm, and a safe-guarded strategy is proposed to detect and compensate for the errors caused by sensor movements. The experimental results obtained from a 3-DoF gimbal and ten healthy subjects demonstrate a promising performance on 3-DoF angle estimation. Specially, the experiments on ten subjects are performed with three gait modes and a 2-min level walking. The root mean square error is below 2 deg for level walking and 5 deg for other two gait modes. The result of 2-min level walking shows our algorithms stability under long run. The robustness against sensor movement are demonstrated through data from multiple sets of IMUs. In addition, results from the 3-DoF gimbal indicate that the accuracy of 3-DoF angle estimation could be improved by 84.9% with our reference frame calibration algorithm. In conclusion, our study proposes and validates a sensor-movement-robust 3-DoF angle estimation for lowerlimb joints based on IMU. To the best of our knowledge, our approach is the first experimental implementation of IMUbased 3-DoF angle estimation for lower-limb joints without calibration.
Motivation & Objective
- To eliminate the need for functional calibration postures in 3-DoF lower limb joint angle estimation using IMUs.
- To address reference frame deviation between IMUs and the earth frame, which causes large errors in joint angle estimation.
- To enable real-time detection and compensation for sensor movements during motion to maintain estimation accuracy.
- To improve the robustness of IMU-based angle estimation against sensor misplacement and dynamic disturbances.
- To develop a self-aligned, calibration-free method suitable for long-term, real-time applications in clinical and wearable settings.
Proposed method
- A feedback-based iterative optimization process estimates the three joint axes of a 3-DoF lower limb joint in real time without requiring functional calibration postures.
- A pointwise reference frame calibration algorithm uses fused gravity and magnetic field vectors to correct time-varying deviations between sensor and reference frames.
- A safe-guarded detection strategy identifies sensor movements by monitoring a variation metric $ V $, which exceeds a predefined threshold when movement occurs.
- During detected movement, a temporary interval $ I_n^{det} $ uses estimates from a detection window to maintain continuity and reduce error propagation.
- The algorithm integrates real-time orientation tracking with biomechanical constraints to compute 3-DoF joint angles in a body-fixed frame.
- A sliding window approach with adaptive interval length $ I_n ∈ [W_n, 800] $ balances real-time performance and estimation accuracy.
Experimental results
Research questions
- RQ1Can 3-DoF lower limb joint angle estimation be achieved without functional calibration postures using only IMU data?
- RQ2How can reference frame deviation between IMUs and the earth frame be effectively compensated in real time?
- RQ3Can sensor movements during motion be detected and corrected online to maintain estimation accuracy?
- RQ4What is the performance of the algorithm under long-duration, continuous motion such as 2-minute level walking?
- RQ5How does the proposed method compare to existing IMU-based approaches in terms of robustness to sensor misplacement and movement?
Key findings
- The algorithm achieved a root mean square error (RMSE) of 1.69° ± 0.90° for hip flexion/extension, 0.52° ± 0.33° for abduction/adduction, and 0.79° ± 0.43° for internal/external rotation during 2-minute level walking.
- For non-level gait modes, the RMSE remained below 5°, with the highest error observed at 5.73° for knee flexion/extension.
- During sensor movement events, the algorithm reduced RMSE from 43.60° (before detection) to 13.97° during the detection interval, demonstrating effective error mitigation.
- The reference frame calibration algorithm improved 3-DoF angle estimation accuracy by 84.9% on a 3-DoF gimbal compared to baseline methods.
- The algorithm maintained stable performance over long runs, with only a slight increase in standard deviation (from 0.77° to 0.83°) in knee flexion/extension across subjects during the 2-minute test.
- Computing time remained within real-time constraints, with a maximum of 6 ms per iteration across different sliding window lengths, confirming feasibility for real-time deployment.
Read this paper