[Paper Review] Sequential Tests of Multiple Hypotheses Controlling False Discovery and Nondiscovery Rates
This paper introduces the Sequential BH Procedure, a novel method for multiple hypothesis testing on streaming data that simultaneously controls both the false discovery rate (FDR) and false nondiscovery rate (FNR) under minimal assumptions. It extends Benjamini-Hochberg's fixed-sample FDR procedure to sequential settings using sequential test statistics, ensuring error control even under arbitrary dependence with a logarithmic inflation factor, and supports flexible sampling schemes including group sequential and truncated designs.
We propose a general and flexible procedure for testing multiple hypotheses about sequential (or streaming) data that simultaneously controls both the false discovery rate (FDR) and false nondiscovery rate (FNR) under minimal assumptions about the data streams which may differ in distribution, dimension, and be dependent. All that is needed is a test statistic for each data stream that controls the conventional type I and II error probabilities, and no information or assumptions are required about the joint distribution of the statistics or data streams. The procedure can be used with sequential, group sequential, truncated, or other sampling schemes. The procedure is a natural extension of Benjamini and Hochberg's (1995) widely-used fixed sample size procedure to the domain of sequential data, with the added benefit of simultaneous FDR and FNR control that sequential sampling affords. We prove the procedure's error control and give some tips for implementation in commonly encountered testing situations.
Motivation & Objective
- To develop a general and flexible procedure for sequential multiple hypothesis testing that controls both FDR and FNR under minimal distributional assumptions.
- To extend the classical Benjamini-Hochberg procedure to sequential data streams while preserving FDR control and adding FNR control.
- To enable application in settings with dependent, non-identically distributed, or high-dimensional data streams without requiring joint distributional assumptions.
- To provide practical implementation guidance for constructing component sequential tests and critical values in common statistical scenarios.
- To demonstrate the procedure’s performance through simulation and compare it with fixed-sample analogs.
Proposed method
- Proposes the Sequential BH Procedure, a sequential extension of Benjamini-Hochberg’s step-up procedure tailored for streaming data.
- Uses individual test statistics per data stream that control conventional type I and II error rates, without requiring joint distributional assumptions.
- Employs sequential sampling with early stopping for rejection (and optionally for non-rejection), enabling dynamic decision-making.
- Applies Wald-type approximations and generalized likelihood ratio statistics to derive critical values for sequential tests.
- Implements a rejective version that controls FDR but not necessarily FNR, useful when FNR control is not a priority.
- Uses recursive bounds and partitioning of sample space to prove FDR and FNR control under independence and with logarithmic inflation under arbitrary dependence.
Experimental results
Research questions
- RQ1Can a sequential multiple testing procedure control both FDR and FNR simultaneously under minimal assumptions about data streams?
- RQ2How can the Benjamini-Hochberg procedure be adapted to sequential or streaming data while preserving FDR control?
- RQ3What is the impact of dependence across data streams on FDR and FNR control in sequential testing?
- RQ4How can critical values for sequential tests be derived in closed form for common statistical models?
- RQ5How does the performance of the sequential procedure compare to its fixed-sample counterpart in terms of error control and power?
Key findings
- The Sequential BH Procedure controls FDR under arbitrary dependence with a logarithmic inflation factor, mirroring the conditions of Benjamini and Hochberg’s original FDR proof.
- Under independence of data streams, the procedure controls FDR at level $\alpha \cdot (K_0 / K)$, where $K_0$ is the number of true null hypotheses and $K$ is the total number of hypotheses.
- The procedure also controls the false nondiscovery rate (FNR) with symmetric proof structure, ensuring simultaneous control of both error rates in the sequential setting.
- The rejective version of the procedure controls FDR but not necessarily FNR, offering a trade-off when FNR control is not required.
- Simulation studies show the procedure maintains strong error control and offers improved efficiency in sequential settings compared to fixed-sample analogs.
- Closed-form critical values are derived for common testing scenarios, enabling practical implementation with minimal computational overhead.
Read this paper
Open the full text in the Nubint reader and ask about any passage as you read.
Read this paper on NubintThis review was generated by AI from the original paper. Please check the paper before citing it.