This paper proposes Sharp U-Net, a depthwise convolutional U-Net variant that applies a sharpening spatial filter to encoder features before skip connection fusion, reducing feature mismatch between low-level and high-level features. The method improves segmentation accuracy in biomedical images without adding learnable parameters, outperforming state-of-the-art models on six datasets with gains up to 12.6% in Dice score.
The U-Net architecture, built upon the fully convolutional network, has proven to be effective in biomedical image segmentation. However, U-Net applies skip connections to merge semantically different low- and high-level convolutional features, resulting in not only blurred feature maps, but also over- and under-segmented target regions. To address these limitations, we propose a simple, yet effective end-to-end depthwise encoder-decoder fully convolutional network architecture, called Sharp U-Net, for binary and multi-class biomedical image segmentation. The key rationale of Sharp U-Net is that instead of applying a plain skip connection, a depthwise convolution of the encoder feature map with a sharpening kernel filter is employed prior to merging the encoder and decoder features, thereby producing a sharpened intermediate feature map of the same size as the encoder map. Using this sharpening filter layer, we are able to not only fuse semantically less dissimilar features, but also to smooth out artifacts throughout the network layers during the early stages of training. Our extensive experiments on six datasets show that the proposed Sharp U-Net model consistently outperforms or matches the recent state-of-the-art baselines in both binary and multi-class segmentation tasks, while adding no extra learnable parameters. Furthermore, Sharp U-Net outperforms baselines that have more than three times the number of learnable parameters.
Motivation & Objective
- To address the issue of blurred feature maps and over/under-segmentation in U-Net caused by fusing semantically dissimilar low- and high-level features.
- To improve feature fusion in U-Net by reducing the semantic gap between encoder and decoder features through spatial sharpening.
- To enhance segmentation performance in both binary and multi-class biomedical image segmentation tasks without increasing model complexity.
- To provide a lightweight, parameter-free enhancement to U-Net that improves feature representation and artifact suppression during early training.
Proposed method
- Introduces a depthwise convolution with a fixed sharpening kernel applied to encoder feature maps prior to skip connection fusion.
- Applies a spatial sharpening filter independently per channel to emphasize fine-grained details in early-stage features.
- Preserves feature map resolution during fusion by maintaining the same spatial dimensions as the encoder output.
- Uses a predefined, non-learnable sharpening kernel to smooth artifacts and improve feature consistency in early training.
- Maintains the standard U-Net encoder-decoder architecture but replaces standard skip connections with sharpened feature fusion.
- Employs standard loss functions (e.g., Jaccard distance) and end-to-end training without architectural or parameter overhead.
Experimental results
Research questions
- RQ1Can applying a spatial sharpening filter to encoder features before skip connection fusion reduce feature mismatch and improve segmentation accuracy?
- RQ2Does the proposed sharpening mechanism reduce blurred feature maps and over/under-segmentation artifacts in biomedical image segmentation?
- RQ3Can a non-learnable, depthwise sharpening layer improve performance without increasing the number of learnable parameters?
- RQ4How does Sharp U-Net compare to state-of-the-art models with significantly more parameters on diverse biomedical image datasets?
Key findings
- Sharp U-Net achieves a 12.6% improvement in Dice score on the CVC-ClinicDB endoscopy dataset, significantly outperforming U-Net and other baselines.
- On the ISBI-2012 dataset, Sharp U-Net improves segmentation performance by 3.63% in Dice score, even in the presence of foreground class imbalance.
- The model consistently outperforms or matches state-of-the-art models across six diverse biomedical image datasets, including EM, endoscopy, dermoscopy, nuclei, CT, and lung segmentation.
- Despite having no additional learnable parameters, Sharp U-Net surpasses models with over three times more parameters in multiple benchmarks.
- Grad-CAM visualization confirms that Sharp U-Net produces more accurate and localized activations in deeper decoder layers, aligning better with ground truth masks.
- The sharpening filter helps suppress artifacts during early training, leading to more stable and refined feature learning throughout the network.