Skip to main content
QUICK REVIEW

[Paper Review] Sparse Phase Retrieval via Truncated Amplitude Flow

Gang Wang, Liang Zhang|arXiv (Cornell University)|Nov 23, 2016
Advanced X-ray Imaging TechniquesPhysics and Astronomy52 references16 citations
TL;DR

This paper proposes SPARTA, a novel sparse phase retrieval algorithm that combines support recovery with truncated amplitude flow to reconstruct sparse signals from magnitude-only measurements. It achieves exact recovery with high probability using $k^2\log n$ Gaussian measurements and runs in $\mathcal{O}(k^2n\log n)$ time, improving computational efficiency by a factor of $k$ over prior methods while remaining robust to bounded noise.

ABSTRACT

This paper develops a novel algorithm, termed \emph{SPARse Truncated Amplitude flow} (SPARTA), to reconstruct a sparse signal from a small number of magnitude-only measurements. It deals with what is also known as sparse phase retrieval (PR), which is \emph{NP-hard} in general and emerges in many science and engineering applications. Upon formulating sparse PR as an amplitude-based nonconvex optimization task, SPARTA works iteratively in two stages: In stage one, the support of the underlying sparse signal is recovered using an analytically well-justified rule, and subsequently, a sparse orthogonality-promoting initialization is obtained via power iterations restricted on the support; and, in the second stage, the initialization is successively refined by means of hard thresholding based gradient-type iterations. SPARTA is a simple yet effective, scalable, and fast sparse PR solver. On the theoretical side, for any $n$-dimensional $k$-sparse ($k\ll n$) signal $\bm{x}$ with minimum (in modulus) nonzero entries on the order of $(1/\sqrt{k})\|\bm{x}\|_2$, SPARTA recovers the signal exactly (up to a global unimodular constant) from about $k^2\log n$ random Gaussian measurements with high probability. Furthermore, SPARTA incurs computational complexity on the order of $k^2n\log n$ with total runtime proportional to the time required to read the data, which improves upon the state-of-the-art by at least a factor of $k$. Finally, SPARTA is robust against additive noise of bounded support. Extensive numerical tests corroborate markedly improved recovery performance and speedups of SPARTA relative to existing alternatives.

Motivation & Objective

  • To address the NP-hard problem of sparse phase retrieval, where only magnitude measurements are available.
  • To develop a scalable and efficient algorithm that achieves exact recovery of sparse signals from minimal measurements.
  • To reduce computational complexity compared to existing nonconvex solvers like TWF and AltMinPhase while maintaining high recovery accuracy.
  • To ensure robustness against bounded additive noise in practical applications.
  • To provide theoretical guarantees on exact recovery under realistic signal and measurement conditions.

Proposed method

  • SPARTA employs a two-stage approach: first, it recovers the support of the sparse signal using an analytically justified rule.
  • Second, it performs sparse orthogonality-promoting initialization via power iterations restricted to the estimated support.
  • The algorithm then refines the initialization using hard thresholding-based gradient-type iterations to maintain sparsity and accelerate convergence.
  • It uses truncated amplitude-based empirical risk minimization to avoid noise amplification in gradient updates.
  • The method leverages dimensionality reduction to accelerate computation while preserving recovery accuracy.
  • It ensures linear convergence by maintaining iterates within a basin of attraction around the global optimum, provided proper step size and truncation threshold are selected.

Experimental results

Research questions

  • RQ1Can a two-stage algorithm combining support recovery and truncated gradient flow achieve exact sparse phase retrieval with fewer measurements than existing methods?
  • RQ2What is the minimal number of random Gaussian measurements required for exact recovery of a $k$-sparse signal using a nonconvex, non-regularized approach?
  • RQ3Can the computational complexity of sparse phase retrieval be reduced by a factor of $k$ compared to state-of-the-art algorithms?
  • RQ4How does SPARTA perform under bounded additive noise, and does it maintain robustness without explicit regularization?
  • RQ5Can theoretical guarantees on convergence and recovery be established for a hard-thresholding-based truncated amplitude flow in the sparse setting?

Key findings

  • SPARTA achieves exact recovery of any $k$-sparse $n$-dimensional signal (up to a global unimodular constant) from approximately $k^2\log n$ random Gaussian measurements with high probability.
  • The algorithm ensures linear convergence of iterates toward the true signal when initialized within a basin of attraction, provided appropriate step size and truncation threshold are used.
  • SPARTA's computational complexity is $\mathcal{O}(k^2n\log n)$, which improves upon the state-of-the-art by a factor of $k$.
  • The method is robust to additive noise with bounded support, maintaining stable performance without requiring explicit noise modeling.
  • Numerical experiments demonstrate that SPARTA significantly outperforms existing alternatives in both recovery accuracy and runtime efficiency.
  • Theoretical analysis confirms that the sparse initialization stage lands within the basin of attraction with high probability, enabling reliable subsequent refinement.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.