QUICK REVIEW
[Paper Review] Sub-100 nm 3-D fluorescence lifetime imaging using time correlated single photon counting detection and multifocal multiphoton excitation
Sunil Kumar|Figshare|Jan 1, 2017
Advanced Fluorescence Microscopy TechniquesBiochemistry, Genetics and Molecular Biology37 references17 citations
TL;DR
This paper presents a 3D fluorescence lifetime imaging technique achieving sub-100 nm spatial resolution by combining time-correlated single photon counting (TCSPC) with multifocal multiphoton excitation. The method enables high-precision, three-dimensional lifetime measurements in biological specimens with enhanced signal-to-noise ratio and reduced photodamage.
ABSTRACT
Abstract removed.
Motivation & Objective
- To achieve sub-100 nm three-dimensional spatial resolution in fluorescence lifetime imaging.
- To overcome the limitations of conventional multiphoton microscopy in depth and lateral resolution.
- To reduce photodamage and photobleaching in live-cell imaging through localized excitation.
- To improve signal-to-noise ratio and temporal resolution using time-correlated single photon counting.
- To enable quantitative 3D lifetime measurements in complex biological samples with high precision.
Proposed method
- Utilizes multifocal multiphoton excitation to create multiple excitation spots simultaneously, increasing imaging speed and signal collection.
- Employs time-correlated single photon counting (TCSPC) for precise measurement of fluorescence decay times.
- Combines TCSPC with a high-precision timing system to resolve nanosecond-scale fluorescence lifetimes.
- Applies a 3D scanning strategy using a multifoci array to achieve volumetric imaging with sub-100 nm resolution.
- Uses a confocal detection scheme to reject out-of-focus fluorescence and improve axial resolution.
- Integrates a high-sensitivity single-photon detector with a histogramming system for lifetime reconstruction.
Experimental results
Research questions
- RQ1Can sub-100 nm 3D spatial resolution be achieved in fluorescence lifetime imaging using TCSPC and multifocal excitation?
- RQ2How does multifocal multiphoton excitation improve signal-to-noise ratio and imaging speed compared to conventional single-spot excitation?
- RQ3To what extent does the technique reduce photodamage and photobleaching in live-cell samples?
- RQ4What is the achievable axial and lateral resolution in 3D lifetime measurements using this setup?
- RQ5Can the method resolve fine subcellular structures based on their fluorescence lifetime differences?
Key findings
- The technique achieves sub-100 nm lateral and axial resolution in 3D fluorescence lifetime imaging.
- Fluorescence lifetime measurements are resolved with nanosecond precision using time-correlated single photon counting.
- Multifocal excitation increases signal collection efficiency and enables faster volumetric imaging.
- The system demonstrates reduced photodamage and photobleaching compared to single-spot multiphoton microscopy.
- The method enables quantitative 3D lifetime mapping of biological specimens with high spatial and temporal fidelity.
- The approach is validated on biological samples, showing resolution and sensitivity suitable for subcellular imaging.
Read this paper
Open the full text in the Nubint reader and ask about any passage as you read.
Read this paper on NubintThis review was generated by AI from the original paper. Please check the paper before citing it.