Skip to main content
QUICK REVIEW

[Paper Review] Test beam results of ATLAS Pixel Sensors

T. Lari|ArXiv.org|Oct 18, 2002
Particle Detector Development and PerformancePhysics and Astronomy1 references8 citations
TL;DR

This paper presents test beam results of ATLAS pixel sensors irradiated to 1.1×10¹⁵ nₑq cm⁻² and 600 kGy, exceeding LHC design fluence and dose. At 600 V bias, the sensors achieved 229 µm depletion depth, 20,000 e⁻ mean collected charge, 98.2% detection efficiency, and 9.6 µm spatial resolution, confirming full compliance with ATLAS performance requirements under extreme radiation conditions.

ABSTRACT

Silicon pixel detectors produced according to the ATLAS Pixel Detector design were tested in a beam at CERN in the framework of the ATLAS collaboration. The detectors used n+/n sensors with oxygenated silicon substrates. The experimental behaviour of the detectors after irradiation to 1.1 10**15 n_eq/cm**2 and 600 kGy is discussed. At the sensor bias voltage of 600 V the depleted depth is measured to be 229 um, the mean collected charge is 20000 electrons, the detection efficiency is 98.2% and the spatial resolution is 9.6 um

Motivation & Objective

  • To evaluate the radiation hardness of ATLAS pixel sensors under conditions exceeding LHC design specifications.
  • To measure the depletion depth, charge collection efficiency, and spatial resolution of irradiated sensors after exposure to 1.1×10¹⁵ nₑq cm⁻² and 600 kGy.
  • To verify that the sensors maintain sufficient performance for vertex reconstruction and trigger efficiency in the high-radiation LHC environment.
  • To assess the impact of the bias grid and sensor geometry on charge collection uniformity.
  • To validate the timing performance of the pixel detector in a 25 ns time window, critical for LHC bunch crossing identification.

Proposed method

  • Irradiated n⁺/n silicon pixel sensors with oxygenated substrates were tested in a 180 GeV/c pion beam at CERN SPS.
  • A beam telescope with 6 µm resolution tracked particles to reconstruct incident track positions and measure residual distributions.
  • Depletion depth was determined from the maximum track segment depth subtended by a pixel, using tracks incident at 30° to the sensor surface.
  • Charge collection efficiency was measured via cluster charge sum, calibrated using known charge injections with 10% accuracy.
  • Detection efficiency was evaluated by measuring the fraction of hits recorded within a 25 ns window relative to a 40 MHz asynchronous clock.
  • Spatial resolution was derived from Gaussian fits to residuals between beam telescope and pixel detector track positions, including charge interpolation effects.

Experimental results

Research questions

  • RQ1Can ATLAS pixel sensors with oxygenated silicon substrates maintain full depletion and adequate charge collection after irradiation to 1.1×10¹⁵ nₑq cm⁻² and 600 kGy?
  • RQ2What is the spatial resolution of the pixel sensors at 10° incidence angle, representative of ATLAS tracking conditions?
  • RQ3How does the presence of the bias grid affect charge collection uniformity across pixel columns?
  • RQ4What is the detection efficiency of the pixel system when operating within a 25 ns time window, as required for LHC bunch crossing identification?
  • RQ5To what extent does charge sharing improve spatial resolution compared to one-pixel cluster reconstruction?

Key findings

  • At 600 V reverse bias, the depletion depth of irradiated sensors reached 229 ± 8 µm, indicating near-full depletion despite radiation damage.
  • The mean collected charge was 20,000 ± 10% electrons at 600 V, representing a 20% reduction from the non-irradiated 25,000 e⁻ baseline.
  • The detection efficiency for hits within a 25 ns window was 98.2%, exceeding the ATLAS requirement of 97%.
  • The spatial resolution was measured at 9.6 µm at a 10° incidence angle, significantly improved by charge interpolation across adjacent pixels.
  • Charge collection uniformity was high except near the bias grid, where signal was reduced due to the presence of the conductive structure.
  • The measured depletion depth scaled with the square root of bias voltage, in agreement with the theoretical model for oxygenated, irradiated silicon.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.